- 15 -
Programming Guide
Programmable Outputs
PGM TEST MODE
PGM DELAY
PGM OPTIONS
In order to use the Flexible PGM Deactivation Option (option [3]), the PGM Deactivation After Option (option [1]) must be ON.
PGM PROGRAMMING
Section
Description
[0901]
Test PGM1: Activates PGM1 for 8 seconds to verify if the PGM is functioning correctly.
[0902]
Test PGM2: Activates PGM2 for 8 seconds to verify if the PGM is functioning correctly.
[0903]
Test PGM3: Activates PGM3 for 8 seconds to verify if the PGM is functioning correctly.
Section
Data
Description
Default
[0918]
__/__/__ ( 001 to 255 x 1 sec./mins.)
PGM1 Delay
(refer to section
[0919]
option
[2]
to see whether the delay is in seconds or minutes)
5 secs./mins.
[0928]
__/__/__ ( 001 to 255 x 1 sec./mins.)
PGM2 Delay
(refer to section
[0929]
option
[2]
to see whether the delay is in seconds or minutes)
5 secs./mins.
[0938]
__/__/__ ( 001 to 255 x 1 sec./mins.)
PGM3 Delay
(refer to section
[0939]
option
[2]
to see whether the delay is in seconds or minutes)
5 secs./mins.
PGM1
[0919]
PGM2
[0929]
PGM3
[0939]
Option
( = Default Setting)
OFF
Disabled
ON
Enabled
OFF
Disabled
ON
Enabled
OFF
Disabled
ON
Enabled
[1]
PGM Deactivation After
(OFF = Deactivation Event; ON = PGM Timer)
N
N
N
[2]
PGM Base Time
(OFF = Seconds; ON = Minutes)
N
N
N
[3]
Flexible PGM Deactivation Option
(OFF = PGM Timer Only; ON =
PGM Timer and/or Deactivation Event)
N
N
N
[4] to [8]
Future Use
N/A
N/A N/A N/A N/A N/A
Event Group
Feature Group
Start #
End #
Section
Section
Section
Section
PGM Activation
PGM1
[0910]
__/__/__
[0911]
__/__/__
[0912]
__/__/__
[0913]
__/__/__
PGM2
[0920]
__/__/__
[0921]
__/__/__
[0922]
__/__/__
[0923]
__/__/__
PGM3
[0930]
__/__/__
[0931]
__/__/__
[0932]
__/__/__
[0933]
__/__/__
PGM Deactivation
PGM1
[0914]
__/__/__
[0915]
__/__/__
[0916]
__/__/__
[0917]
__/__/__
PGM2
[0924]
__/__/__
[0925]
__/__/__
[0926]
__/__/__
[0927]
__/__/__
PGM3
[0934]
__/__/__
[0935]
__/__/__
[0936]
__/__/__
[0937]
__/__/__
Event Group
Event
Feature Group
Feature
Start #
End #
000
Zone is OK
000
255 = any Zone #
Zone Numbers
001 to 096
001 to 096
001
Zone is Open
001 to 096
001 to 096
002
Zone is Tampered
001 to 096
001 to 096
003
Zone is in Fire Loop Trouble
001 to 096
001 to 096
004
Non-reportable Event
000
TLM Trouble
000
000
Smoke detector reset
001
001
Arm with no entry delay
002
002
Arm in Stay mode
003
003
Arm in Away mode
004
004
Full arm when in Stay mode
005
005
Voice module access
006
006
Remote control access
007