background image

 EVO Systems 3

2.0 Basic Operation

The following sections will introduce you to the functions of the buttons, lights, and messages on your keypad.

Figure 1: LCD Keypad Basic Overview

Figure 2: DGP2-648BL LED Keypad Overview

The LCD screen will guide you 
with detailed messages.

Use the arrow buttons to scroll 
through the current menu when the 
arrows appear in the LCD screen.

AC Light:
ON 

= AC power

OFF 

= Power failure

STATUS Light:
When Green:
ON 

= All zones are closed.

OFF 

= One or more zones are 

open.
FLASH 

= Exit Delay in progress

When Red:
ON = 

Area(s) 

armed

OFF = 

Area(s) 

disarmed

 

The keypad will display the status

 of all its assigned areas.

ACTION Lights: (Access, Stay, 
Force, Byp, Mem, Trbl and Prg)
Lights will illuminate according to 
the status of the system.

Numerical Lights: (Zones) 
ON 

= Zone is open

OFF 

= Zone is closed (OK)

FLASHES  = Zone / fire loop

AC Light:
ON = AC Power (OK)
OFF 

= Power failure

AREA Lights: (A1, A2, A3 and A4)
ON = Area armed
OFF = 

Area 

disarmed

FLASH 

= Area in alarm

STATUS Light:
When green:
ON 

= All zones closed

OFF 

= One or more zones are 

open
FLASH 

= Exit Delay in progress

When red:
ON 

= Area(s) armed

OFF 

= Area(s) disarmed

FLASH

= System in Alarm

For all keypads, the 

[

ENTER

]

 key will save and exit, and the 

[

CLEAR

]

 key will exit without saving. 

[

ENTER

and

 [

CLEAR

represent the LCD/LED keypads’ enter and clear keys unless both keys are 

shown to have a different function.

Содержание Digiplex EVO EVO48

Страница 1: ...We hope this product performs to your complete satisfaction Should you have any questions or comments please visit www paradox com and send us your comments EVO48 EVO192 User Guide...

Страница 2: ......

Страница 3: ...ng Exiting 17 Arming and Disarming with Card 17 How Access Control Works 18 Trouble Display 19 Trouble Display 19 Event Record Display 20 Additional Features 21 Programmable Outputs PGMs 21 Keypad Set...

Страница 4: ...essages and menus to guide you through the system s operations Your installer can even customize the messages on LCD keypads for your home or business The LED display of the DGP2 648BL will let you as...

Страница 5: ...keypad will display the status of all its assigned areas ACTION Lights Access Stay Force Byp Mem Trbl and Prg Lights will illuminate according to the status of the system Numerical Lights Zones ON Zo...

Страница 6: ...the system reverts to a previous status or when an operation is incorrectly entered the keypad emits a continuous beep tone BEEEEEEEEEEP 2 2 Confidential Mode Your installer can program keypads to not...

Страница 7: ...Sleep Arming Indicators 3 3 Other Indicators Action LED Sequence Auditory Sequence Disarming Green on Two beeps Exit delay Red green slow flash Confirmation beep Arming Entry Delay Red on Confirmation...

Страница 8: ...s ENTER when the area you want to view appears on the screen 3 Press CLEAR to exit In Area Status Display mode the following information will scroll on the LCD screen ready if all zones in the selecte...

Страница 9: ...u have access to more than one area select the area s you wish to Stay arm refer to section 4 1 on page 6 5 4 Instant Arming This feature is the same as Stay arming except that there is no Entry Delay...

Страница 10: ...all reinstates the zones that were bypassed the last time your system was armed To activate Bypass Recall 1 Enter your ACCESS CODE 2 Press the BYP button 3 Press the MEM button Zones bypassed the last...

Страница 11: ...he ACC button when the area you want to program appears on the screen 5 Enter the time you want the area to be armed according to the 24 hour clock i e 9 a m is 09 00 and 9 p m is 21 00 6 Press the EN...

Страница 12: ...r ACCESS CODE 2 In the case of a false alarm call your monitoring station quickly to advise them of the false alarm In the case of a burglar alarm leave the premises and call the Police from a safe lo...

Страница 13: ...other options are manually changed the System Master Code will immediately revert to its original programming You can assign a label name to a user access code at any point during the Programming User...

Страница 14: ...cursor position FORCE Delete Pressing the FORCE key will delete the character or blank space found at the current cursor position ARM Delete Until the End Pressing the ARM key will delete all characte...

Страница 15: ...that they are assigned to For example if a User with the Master feature is assigned User Option 1 and Area 2 they can only assign Option 1 and Area 2 to a user access code 032 048 064 080 096 112 128...

Страница 16: ...d if PGMs are programmed by your installer the user can only control the PGMs Refer to section 10 1 on page 21 for a more detailed explanation of PGMs User Options see section 7 7 on page User Labels...

Страница 17: ...s Option 6 Stay Instant Arm When option 6 is ON the Stay and Instant arm features are enabled The user can now Stay or Instant arm their assigned areas Option 7 Force Arm When option 7 is ON the Force...

Страница 18: ...ature extends a user s scheduled access period through an Access Control door by the amount programmed by your installer For example if the user s assigned schedule for the door is Monday to Friday fr...

Страница 19: ...ming and Disarming with Card 8 2 1 Arming with Card presented to a door during its assigned Schedule refer to step 8 in section 7 5 1 on page 14 presented to a door within its assigned Access Level re...

Страница 20: ...e EVO641R DGP2 641RB keypad on Door 02 on Tuesday August 3 at 3 00 p m she will gain access to the room Figure 4 Example B If Bonnie presents her card to the reader or the EVO641R DGP2 641RB keypad on...

Страница 21: ...m serviced 9 1 1 Group 1 System 1 AC Failure The control panel has detected a power failure This means that your system is running on the backup battery If this trouble occurs when your establishment...

Страница 22: ...cess Granted You will only be able to view the events that occurred in the area s assigned to your user access code Only available on LCD keypads To view the Event Record 1 Enter your ACCESS CODE 2 Pr...

Страница 23: ...ODE Your keypad will emit a Confirmation Beep The ACCESS action light will flash 2 Press the 6 key Your keypad will emit a Confirmation Beep the Prg action light will illuminate and the numerical ligh...

Страница 24: ...s will stop beeping when opened HH MM 4 Press CLEAR to exit chime programming 10 6 Panic Alarms Your system can be programmed to send an alarm to your monitoring station to request help from the poli...

Страница 25: ...set by your installer 4 When the VDMP3 answers the line you are prompted to enter your access code 5 Options are given to arm disarm 1 and control features PGMs 2 Not connected to an answering machine...

Страница 26: ...24 User Guide...

Страница 27: ...use your system requires no maintenance other than regular testing We recommend that your installer change the battery every three years 12 4 System Test Speak to your installer before conducting a S...

Страница 28: ...ke detector 3 If the problem remains after 90 seconds the alarm will sound again Press CLEAR again 4 The system will delay reporting the alert for another 30 seconds If you are unable to cancel the fa...

Страница 29: ...ires 13 5 Home Fire Warning System Household fires are especially dangerous at night Fires produce smoke and deadly gases that can overcome occupants while they sleep To warn against fire install smok...

Страница 30: ...41 034 050 066 082 098 114 162 178 194 210 226 242 035 051 067 083 099 115 163 179 195 211 227 243 036 052 068 084 100 116 164 180 196 212 228 244 037 053 069 085 101 117 165 181 197 213 229 245 038 0...

Страница 31: ...241 034 050 066 082 098 114 162 178 194 210 226 242 035 051 067 083 099 115 163 179 195 211 227 243 036 052 068 084 100 116 164 180 196 212 228 244 037 053 A069 085 101 117 165 181 197 213 229 245 03...

Страница 32: ...14 130 146 162 178 194 210 226 242 019 035 051 067 083 099 115 131 147 163 179 195 211 227 243 020 036 052 068 084 100 116 132 148 164 180 196 212 228 244 021 037 053 A069 085 101 117 133 149 165 181...

Страница 33: ...ouch 8 Quick Function 22 Bypass Bypass Recall 8 Programming 7 C Card Access Control Arming with 17 Disarming with 17 Characters Special 13 Chime Zones 22 Clock Set Time and Date 21 Code Follows Schedu...

Страница 34: ...al Characters 13 Special Characters Greek 30 Special Characters Hebrew 28 Special Characters Russian 29 Special Function Keys 12 Standard Fire Zone 26 Stay Arming 7 System Master Code 11 System Test 2...

Страница 35: ...com Terms Warning for Connections to Non Traditional Telephony eg VoIP Paradox alarm equipment was designed to work effectively around traditional telephone systems For those customers who are using...

Страница 36: ...rt in Canada or the U S call 1 800 791 1919 Monday to Friday from 8 00 a m to 8 00 p m EST For technical support outside Canada and the U S call 00 1 450 491 7444 Monday to Friday from 8 00 a m to 8 0...

Отзывы: