2 Reference & Installation Manual

2.0 Installation

2.1 Connecting the Keypad

The LED keypad is connected to the control panel’s communication 
bus in a star and/or daisy chain configuration. The four-wire 
communication bus provides power and two-way communication 
between the control panel and all modules connected to it. Connect the 
four terminals labeled 

red

black

green

 and 

yellow

 of the keypad to 

the corresponding terminals on the control panel as shown in Figure 1 
on page 3. Refe
r to the control panel’s

 Reference & Installation Manual

 

for the maximum allowable installation distance from the control panel.

2.2 Connecting the Keypad Zone

Your keypad has one hardwired input terminal, allowing you to 
connect one detector or door contact directly to it. For example, you 
can wire a door contact located at the entry point of an establishment 
directly to the input terminal of the entry point keypad, instead of 
wiring the door contact all the way to the control panel.

Connect the device to the keypad's input terminal as shown in Figure 
1 on page 3.

The keypad zone follows the control panel’s EOL 
definition.

In order to communicate its status to the control panel, devices 
connected to the keypad's input terminal must be assigned to a zone 
in the control panel and the zone's parameters must be defined.

The control panel does not recognize tampers 
originating from the keypad zone.

For more information on zone assignment, please refer to the control 
panel's

 Reference & Installation Manual

. Please note that even with 

DGP2648_EI06.fm  Page 2  Thursday, July 22, 2004  9:15 AM

Содержание Digiplex DGP2-648

Страница 1: ...for DGP 848 DGP NE96 systems 48 Zone LED Keypad V1 0 Installer Guide DGP2 648 DGP 641 DGP2648_EI06 fm Page 3 Thursday July 22 2004 9 15 AM...

Страница 2: ...DGP2648_EI06 fm Page 2 Thursday July 22 2004 9 15 AM...

Страница 3: ...Display 7 Section Reset 7 Confidential Mode 8 Exit Confidential Mode 8 Confidential Mode Timer 8 Muting 9 Beep on Exit Delay 9 Chime on Zone Closure 9 Beep on Trouble 9 Keypad Anti tamper Enable 10 P...

Страница 4: ...DGP2648_EI06 fm Page 0 Thursday July 22 2004 9 15 AM...

Страница 5: ...ng LEDs provide the system s status at a glance 1 1 Specifications Power input 9 16 Vdc 45mA typical PGM current limit 50 mA Number of inputs 1 Number of zones 1 standard zone no tamper recognition Po...

Страница 6: ...l allowing you to connect one detector or door contact directly to it For example you can wire a door contact located at the entry point of an establishment directly to the input terminal of the entry...

Страница 7: ...it If the current drawn will exceed the current limit a relay should be connected to the PGM as shown in Figure 1 on page 3 Devices connected to a keypad s input terminal must be assigned to a zone ke...

Страница 8: ...ort installer programming capabilities therefore you cannot program other modules or the panel on the communication bus using this unit 3 1 Winload Programming Using the WinLoad Security System Manage...

Страница 9: ...Access Stay Force Mem Trbl and Prg Lights will illuminate according to the status of the system Numerical Lights Zones ON Open breached OFF OK FLASHES Tamper fire loop AC Light ON AC Power OFF Power...

Страница 10: ...nts LED numbers A1 to A4 respectively Figure 3 LED Partition Display Do not assign the same display number to more than one section For example you cannot assign value 002 to sections 003 and 004 The...

Страница 11: ...d you that a selected LED number is already assigned to another section Refer to section 6 0 on page 14 for default values Example LED number 29 is assigned to zone 29 To reassign LED number 29 to zon...

Страница 12: ...al mode is enabled option 2 determines how the keypad will return to normal mode after the keypad has switched to confidential mode see section 4 4 Option 2 ON Exit Confidential Mode by entering an ac...

Страница 13: ...ed Option 4 OFF Exit Delay beep disabled Option 4 ON Exit Delay beep enabled default 4 9 Chime on Zone Closure Section 009 Option 5 During the Chime Zone Time Period that the user sets the keypad can...

Страница 14: ...tion 2 OFF Disabled default Option 2 ON Enabled Module Communication Bus Troubles Option 3 OFF Disabled default Option 3 ON Enabled Zone Troubles Option 4 OFF Disabled default Option 4 ON Enabled 4 11...

Страница 15: ...y Closed 5 2 PGM Activation Event SECTION 014 to 017 Modules belonging to the DGP2 series are programmed using the PGM Programming table in the Digiplex DigiplexNE Modules Programming Guide The PGM Ac...

Страница 16: ...n the Feature Group Use the PGM Programming Table in the Digiplex DigiplexNE Modules Programming Guide to program the keypad s PGM Deactivation Event Enter the sections that correspond to the EVENT GR...

Страница 17: ...the value programmed in section 013 represents how long the PGM will remain in its opposite state see PGM State on page 11 after being activated To program the timer enter a 3 digit decimal value 001...

Страница 18: ...ED A1 002 PARTITION 2 DISPLAYED ON __ __ __ 002 LED A2 003 PARTITION 3 DISPLAYED ON __ __ __ 003 LED A3 004 PARTITION 4 DISPLAYED ON __ __ __ 004 LED A4 005 PARTITION 5 DISPLAYED ON __ __ __ 000 006 P...

Страница 19: ...P ON EXIT DELAY DISABLED U ENABLED 5 CHIME ON ZONE CLOSURE U DISABLED ENABLED 6 TO 8 N A Section 010 Beep on Trouble Option Description OFF ON 1 BEEP ON SYSTEM TROUBLES CLOCK LOSS U DISABLED ENABLED 2...

Страница 20: ...ON MODE U DEACTIVATION EVENT PGM TIMER 3 PGM BASE TIME U 1 SECOND 1 MINUTE 4 N A 5 KEYPAD ANTI TAMPER U DISABLED ENABLED 6 TO 8 N A Section Data Description Default 012 __ __ __ 005 255 CONFIDENTIAL M...

Страница 21: ...ACTIVATION EVENT PGM START NUMBER 000 017 __ __ __ 000 255 ACTIVATION EVENT PGM END NUMBER 000 018 __ __ __ 000 255 DEACTIVATION EVENT PGM EVENT 000 019 __ __ __ 000 255 DEACTIVATION EVENT FEATURE GRO...

Страница 22: ...5 __ __ __ ZONE 5 119 __ __ __ ZONE 19 106 __ __ __ ZONE 6 120 __ __ __ ZONE 20 107 __ __ __ ZONE 7 121 __ __ __ ZONE 21 108 __ __ __ ZONE 8 122 __ __ __ ZONE 22 109 __ __ __ ZONE 9 123 __ __ __ ZONE...

Страница 23: ...__ __ ZONE 37 159 __ __ __ ZONE 59 138 __ __ __ ZONE 38 160 __ __ __ ZONE 60 139 __ __ __ ZONE 39 161 __ __ __ ZONE 61 140 __ __ __ ZONE 40 162 __ __ __ ZONE 62 141 __ __ __ ZONE 41 163 __ __ __ ZONE...

Страница 24: ...ONE 87 175 __ __ __ ZONE 75 188 __ __ __ ZONE 88 176 __ __ __ ZONE 76 189 __ __ __ ZONE 89 177 __ __ __ ZONE 77 190 __ __ __ ZONE 90 178 __ __ __ ZONE 78 191 __ __ __ ZONE 91 179 __ __ __ ZONE 79 192...

Страница 25: ...y other person for any loss or damages whether direct or indirect or consequential or incidental including without limitation any damages for lost profits stolen goods or claims by any other party cau...

Страница 26: ...Notes DGP2648_EI06 fm Page 22 Thursday July 22 2004 9 15 AM...

Страница 27: ...DGP2648_EI06 fm Page 23 Thursday July 22 2004 9 15 AM...

Страница 28: ...al support outside Canada and the U S call 00 1 450 491 7444 Monday to Friday from 8 00 a m to 8 00 p m EST Please feel free to visit our website at www paradox ca 780 Industriel Blvd Saint Eustache Q...

Отзывы: