Esprit 728 Ultra & 738 Ultra
23
6.9.7
Trouble/Trouble Restore Codes
Streamline - Sections 60 to 63
D
Hex Programming - Addresses 496 to 511
Each of the these addresses represent a specific trouble or restore condition. The control panel will report the
appropriate event code to the monitoring station when one of the following conditions occurs or after the condition has
returned to normal.
496 -
Max. Auxiliary Current: The current draw from auxiliary is greater than or equal to 650mA (728 Ultra) or
700mA (738 Ultra)
497 -
Bell Disconnect/Max. Bell Current: Bell is disconnected or bell current is greater than or equal to 3A
498 -
Battery Disconnect/Low Voltage: Battery disconnected or battery voltage less than or equal to 10.5V
499 -
Power Failure: Voltage on AC input is less than or equal to 12.5V
500 -
Fire Loop Trouble (728 Ultra): A tamper occurs on a fire zone (Zone 3/24Hr or Zone 5/24Hr if 2-wire with ATZ)
Fire Loop Trouble (738 Ultra): A tamper occurs on a fire zone (Zone 3/24Hr)
501 -
Timer Loss: The control panel detects a loss in the panel timer
502 & 503 -
Reserved for future use
504 -
Max. Auxiliary Current Restore
505 -
Bell Disconnect Restore: No restore code for bell current
506 -
Battery Disconnect/Low Voltage Restore
507 -
Power
Failure
Restore
508 -
Fire Loop Trouble Restore
509 -
Timer
Programmed
510 -
on page 22) have returned to normal
511 -
TLM Trouble Restore: Telephone line has restored after the TLM (see
Telephone Line Monitoring (TLM)
on page 37) has detected the loss of a telephone line
6.9.8
Special Codes
Streamline - Sections 64 to 67
D
Hex Programming - Addresses 512 to 527
Each address represents a special condition in the system. When one of these special conditions occur, the control
panel will report the event code associated with the address.
512 -
Test Report: The test report has been activated either manually (see
on page 24) or
automatically (see
513 -
Panic 1: Keys
[1]
and
[3]
are pressed to activate a Panic 1 alarm
514 -
Panic 2: Keys
[4]
and
[6]
are pressed to activate a Panic 2 alarm (see
515 -
Panic 3: Keys
[7]
and
[9]
are pressed to activate a Panic 3 alarm
516 -
Late To Close: Timed Auto Arming (see page 32) is enabled and the system has not automatically armed
itself at the specified time
517 -
No Movement: No Movement Auto Arming (see page 32) is enabled and no movement has occurred for
the designated amount of time
518 -
Partial Arming: Whenever the system is Force/Away armed, Stay armed, or armed while one or more
zones are bypassed
519 -
Recent Close: An alarm occurs shortly after the system has been armed (see
520 -
Duress: The Duress feature is enabled (see
on page 11) and a user disarms the system using the
User code #48
521-
Closing Delinquency: When the last time the system was armed is greater than the programmed Closing
Delinquency Timer (see page 34)
522 & 523 -
Reserved for future use
524 -
Log-In (Espload): Espload software is used to communicate with the control panel
525 -
Program Change: The Installer code is used to enter the programming mode
526 & 527 -
Reserved for future use
6.10
Auto Test Report
Decimal Programming
D
Addresses 046 to 048
(Default: Auto Test Report Disabled)
Feature Select Programming
D
Address 090; Key
[3]
(Default: OFF)
The report code programmed at address 512 will be reported to the monitoring station after a specified period of time has
elapsed. Depending on whether address 090 key
[3]
is ON or OFF, this specified time can be in days or hours. Also note that if
[2
ND
]
is programmed at address 512 nothing will be reported.
738 Ultra: Address 046 can be set from 001 to 254. 255 is reserved for setting the Timed Test Transmission (see
page 24) when the system is armed or disarmed.
Address 090 Key
[3]
OFF:
The Auto Test report will be transmitted after the number of days programmed at address 046 and the
time programmed at address 047 (hours) and 048 (minutes) has elapsed. To disable this feature, program 000 at address 046.
[
ENTER
]
+ Installer code +
[0] [4] [6]
+ 3 digits (days) +
[0] [4] [7]
+ 3 digits (hours) +
[0] [4] [8]
+ 3 digits (minutes) +
[
ENTER
]