background image

30  

  Operating the Double Burner 

GSL-SB2B Double Side Burner Operator Manual 

Open the LP gas cylinder compartment door to inspect the gas supply 

hose before each use of the burner unit. If there is evidence of 

abrasion or wear, or if the hose is cut, it must be replaced before 

operating the burner unit. Refer to the LP Gas section on page 25.  

 

Lighting the Burner unit 

Prior to lighting your burner unit for the first time, verify that all of the following are complete and correct: 

 All packaging has been removed 

 Proper gas supply and regulator type are in place 

 The gas connection is complete, securely tightened, and leak tested (see Leak Test on page 27) 

 All parts and components are properly in place 

 Manual gas shut-off valve is fully accessible 

 The LP gas hose is clean and free of cuts, wear, abrasion, or leaks. Replace if necessary with a suitable UL, 

ETL, or CSA Listed part with 3/8” internally threaded connector 

 

 

IF YOU SMELL GAS: 

  Immediately shut off the gas supply to the appliance at its 

source 

  Extinguish any open flames 

  Open all access doors and drawers to release any 

accumulation of gas vapor 

  If a gas odor persists, keep away from your appliance and 

contact your gas supplier or fire department immediately

 

Failure to remove the burner cover before lighting the burners, or not 

waiting 15 minutes to allow gas to clear if a burner does not light, may 

result in a fire or explosion causing serious bodily injury, death and/or 

property damage. 

 

Содержание GSL-SB2B

Страница 1: ...GSL SB2B Double Side Burner PROFESSIONAL Operator Manual ...

Страница 2: ...S FOR FUTURE REFERENCE You are responsible for checking updates and revisions available online at http www paradisegrillsdirect com owners Serial number ______________________________________ See information label on burner assembly for serial number Purchase date ______________________________________ DANGER WARNING If you smell gas Shut off gas to the appliance Extinguish any open flame Open lid...

Страница 3: ...nder 10 LP Cylinder Mount 10 Gas Regulator 11 Installation 11 Outdoor Rated Electric Cord 12 Safety Equipment 12 Covers 12 Grill Island Preparation 13 Paradise Grills Island Ventilation 13 Double Burner Location 14 Clearances 15 Custom Island Construction 15 Planning Considerations 15 Custom built Island Ventilation 16 Custom built Island Cut outs 17 Double Side Burner Dimensions 17 Double Side Bu...

Страница 4: ...ble Burner 32 Stainless Steel Maintenance 32 Corrosive Environmental Conditions 33 Clean the Double Burner Exterior 33 Clean the Drip Tray 33 Preventive Maintenance 34 Ventilation 34 Burner Inspection 34 Spiders and Other Insects 34 Troubleshooting 35 Adjust the Burner Orifice 35 Convert to Another Gas Type 36 Double Side Burner Diagram 39 Limited Manufacturer s Warranty 40 Limited Warranty 40 War...

Страница 5: ...r property damage An imminently hazardous situation which if not avoided will result in death or serious injury or property damage Operational Warnings All users must read this entire manual before attempting to operate the burner unit Follow these safety precautions every time the burner unit is used IF YOU SMELL GAS 1 Immediately shut off the gas supply to the appliance at its source 2 Immediate...

Страница 6: ... Do not use the burner unit as storage area for flammable materials Keep area clear and free from combustible materials gasoline and other flammable vapors and liquids Failure to do so can result in death explosion or fire All appliance surfaces will get hot during use Use extreme caution when operating the appliance Do not touch hot surfaces CALIFORNIA PROPOSITION 65 Combustible by products produ...

Страница 7: ...pment that will be connected to that line Do not use piping with less than 1 2 inside diameter or 1 outside diameter to connect this burner unit to NG supply line Do not use any tape pipe dope or threading compound on any flare threads doing so may cause a clog in the regulator and prevent your burner unit from safe and proper operation Any pressure testing must be performed only by a qualified ga...

Страница 8: ...w these instructions may result in explosion personal injury or death If a gas leak cannot be stopped by closing the LP cylinder valve immediately leave the area and call the fire department To replace an LP gas cylinder 1 Turn all burner knobs to OFF and close the LP cylinder valve 2 Disconnect the regulator hose from the LP cylinder 3 Remove cylinder from the enclosure have it replaced or filled...

Страница 9: ...e a spare LP cylinder indoors or within the burner unit enclosure When attaching components ensure all connections are secured and fully tightened to prevent leakage Turn off the gas supply Natural Gas or LP Gas when burner unit is not in use Leak Testing Test all gas piping and connections for leaks after installation or service for both NG and LP gas systems Never use an open flame to check for ...

Страница 10: ...other appliance Follow these precautions when transporting or storing an LP gas cylinder Transport only one cylinder at a time Ensure the cylinder is secured in an upright position with the control valve turned off and the dust cover in place Store cylinders outdoors in a protected cool and dry location out of reach of children Do not store cylinders in a building garage or any other enclosed area...

Страница 11: ...Dimensions 12 5 8 W x 25 D x 12 3 8 H Total BTU Output 24 000 BTU Number of Burners 12 000 BTU x 2 Orifice Size mm LP 1 05 mm Orifice Size mm NG 1 6 mm Drip Tray Stainless Steel Burner Aluminum and Brass Ignitor Piezo Ignition System Warranty See page 40 for details Limited Lifetime Warranty on stainless steel housing 5 years on burners 1 year on all other parts Gas Type Available in LP or NG ...

Страница 12: ...n of Dangerous Goods See the LP cylinder collar for marking Figure 2 LP Gas Cylinder Requirements LP cylinder valve must have o Type 1 outlet compatible with regulator or burner unit o Safety relief valve UL listed Overfill Protection Device OPD identified by a unique triangular hand wheel Figure 2 right Use only LP cylinders equipped with this type of valve LP cylinder must be upright for vapor w...

Страница 13: ...cted to a separate regulated supply line and LP tank Natural Gas A grill configured for natural gas NG supply comes with a manufacturer supplied regulator right set for 4 water column pressure If installed with a NG grill the NG burner unit may be connected to the grill s regulated supply line via a T adapter or connected to its own separate NG supply line Installation Operating a gas cooking appl...

Страница 14: ...round Fault Circuit Interrupter GFCI electrical outlet installed This electrical box has a hanging plug pigtail for connection to an existing GFCI electrical outlet for power supply The customer must supply an outdoor rated extension cord long enough to reach your chosen electrical outlet Use only a 12 gauge extension cord with a grounded 3 prong plug Outdoor extension cords should be used with ou...

Страница 15: ...gure 4 a Use the provided adjustable footers to ensure the island s entire bottom edge on all sides is always at least 1 above the ground b Open gap spacing under the burner unit head and side burners if installed c Open gap spacing around the refrigerator if applicable Figure 4 Paradise Grills Island Venting Example The island s entire bottom edge on all sides must always be maintained at least 1...

Страница 16: ...rrier wind deflector or wind guard Winds directly hitting the back of the burner unit may cause unsafe and improper operation This burner unit is designed for outdoor use only DO NOT use this burner unit inside a building garage or enclosed area DO NOT use this burner unit in or on a recreational vehicle trailer boat or any other moving installation As with any gas cooking appliance harmful carbon...

Страница 17: ... The following planning considerations are provided as general information only You must consult with a licensed contractor to ensure safe and proper design construction ventilation and installation in accordance with all applicable codes Because the amount of venting required varies on a case by case basis consult with a licensed contractor and local codes for adequate ventilation requirements Ke...

Страница 18: ...red at the gas supply connection point Partial enclosures Many backyards have areas that are partially closed off such as balconies and pergolas In some cases it is hard to decide whether these partially enclosed areas should be classified as indoor areas particularly in terms of permanent non closable ventilation If you are in doubt consult your local codes or a licensed contractor for guidance M...

Страница 19: ...ofessional and local codes for adequacy requirements Ensure your outdoor kitchen is constructed out of non combustible materials If your outdoor kitchen is constructed of any combustible materials an insulated jacket is REQUIRED Cutout dimensions do not allow for lid clearance or other measurement requirements See Double Side Burner Dimensions for specifics Please allow for a tolerance of 1 8 we r...

Страница 20: ...or any damage that occurs during shipment If damages are unnoticed until the product is unpacked notify the delivery company immediately and file a concealed damage claim with them within 5 days of the delivery date Keep the box and shipping materials for inspection All out of box claims must be made prior to installation Any product installed in a damaged condition will be deemed to have been dam...

Страница 21: ...te 2 Carefully snip the zip ties around the electrical cable inside the left rear corner of the burner unit Figure 11 DO NOT CUT THE WIRE Figure 11 Electrical Cable 3 Attach the gas supply line to the burner unit per Connect Burner Unit to Gas Source procedure on page 23 The burner unit is heavy and requires two people to lift and to avoid injury and damage to the burner unit and island Pinch Haza...

Страница 22: ...t d Slide the burner unit all the way back into place in the cut out 5 Check to ensure the burner unit is level and properly supported around the entire outside edge of the cut out If the burner unit is not level or is unstable use non combustible shims under the outside lip to level and stabilize it Proper leveling of your burner unit is essential to its safe and proper operation a non level burn...

Страница 23: ...er unit plug with the power supply holes Figure 14 left b Insert the plug until it is fully seated Figure 14 center c Slide the gnarled locking nut to the threads and hand tighten until it stops do not force 8 Plug in the LED light power supply and test the lights press the light button to turn on the control knob lights press again to turn them off Figure 15 Figure 15 Light Control ...

Страница 24: ...appliance malfunctions or has been damaged in any manner contact Paradise Grills to discuss service options or call a licensed professional for inspection and repair Do not let the cord hang over the edge of a table or touch hot surfaces When connecting first connect plug to the outdoor cooking gas appliance then plug appliance into the outlet Use only a GFCI protected circuit with this outdoor co...

Страница 25: ... Maximum Pressure Minimum Pressure Natural Gas NG 4 w c 4 w c Liquid Propane LP 11 w c 11 w c The burner unit is set at the factory for the type of gas supply to be used Be sure the marking on the burner unit s rating plate Figure 16 matches the gas type being supplied to the burner unit either NG or LP All gas installations connections conversions and adjustments must be performed by a qualified ...

Страница 26: ...r gas supply dealer and use a licensed contractor or installer if you desire to convert your burner unit to LP gas supply Burner units operated with LP gas require an LP regulator set to 11 0 water column pressure The self contained LP system burner unit is designed to be used with a standard 20 lb 12 1 4 diameter 18 high cylinder with right handed connection threads this is the maximum size LP ta...

Страница 27: ...ng Doing so may cause a clog in the regulator and prevent your burner unit from safe and proper operation To connect the burner unit to a natural gas source 1 Ensure all burner unit control valves are in the OFF position 2 Connect a suitable natural gas flex connector to the burner unit gas inlet connection Figure 17 Natural Gas Connection Turn on the main gas supply and check all connections for ...

Страница 28: ...er Never store the burner unit indoors with the LP gas cylinder connected Always disconnect and remove the LP gas cylinder from the burner unit before storing the burner unit indoors 2 Ensure all burner unit control valves are in the OFF position 3 Turn the LP cylinder OFF by turning the hand wheel clockwise until it stops 4 Remove the safety cap from the LP cylinder valve below left 5 Insert the ...

Страница 29: ... cylinder must be returned to a proper LP tank supplier and replaced Always conduct the leak test outdoors in a well ventilated area Perform a leak test before first use and at least once a year whether the LP gas supply cylinder has been disconnected or not whenever the gas cylinder is connected to the regulator and whenever any part of the gas system is disconnected or replaced The leak test sho...

Страница 30: ...er orifices remove the grate and burners per the Convert to Another Gas Type procedure on page 36 6 Looking below the burners Figure 22 spray each orifice with soapy water to check for bubbles Figure 22 Burner Orifice Leak Test 7 Make note of the location of any leaks indicated by growing bubbles and turn off the gas supply 8 Contact a qualified gas technician to tighten any loose connections or r...

Страница 31: ...operating your gas burner unit to prevent injury and appliance damage Do not leave an operating burner unit unattended Close supervision is necessary when this or any appliance is used near children Keep children away from the burner unit during operation and until the unit has cooled off Do not store any unconnected LP cylinder or tank in the vicinity of this unit or any other appliance Never sto...

Страница 32: ...ted see Leak Test on page 27 All parts and components are properly in place Manual gas shut off valve is fully accessible The LP gas hose is clean and free of cuts wear abrasion or leaks Replace if necessary with a suitable UL ETL or CSA Listed part with 3 8 internally threaded connector IF YOU SMELL GAS Immediately shut off the gas supply to the appliance at its source Extinguish any open flames ...

Страница 33: ...ight the rear burner You will hear a loud click as the igniter produces the ignition spark Right knob controls the REAR burner Left knob controls the FRONT burner 6 Watch the burner to confirm ignition if the burner does not light on the first try turn the knob OFF wait 2 minutes and repeat 7 Repeat step 4 to light the front burner 8 If the burner does not light on the second try push in both burn...

Страница 34: ...er of chromium oxide protects stainless steel from corrosion Oxygen from the atmosphere combines with the chromium in the stainless steel to form a protective chromium oxide film This protection will be reduced by any contamination of the surface by corrosive agents such as dirt fertilizers chlorine pesticides high salt content air and or other corrosive substances Any contamination of the surface...

Страница 35: ... air high salt content air fertilizers pesticides corrosive cleaning solutions and masonry dust and debris may cause the stainless steel to develop surface oxidation rust corrosion and pitting To minimize such issues Regularly wipe down the burner unit s stainless steel with a damp cloth or non abrasive micro fiber towel Allow the surfaces to dry before covering the burner unit Do not cover a damp...

Страница 36: ... opening s are free and clear from debris Burner Inspection Visually check burner flames for correct operation at least twice per year When lit the flame should have a bluish color to it If the flame has a tint of yellow adjustment can be made to obtain a blue flame and proper gas flow See the Troubleshooting section Inspect the burners if the burner unit has not been used for more than a month or...

Страница 37: ...nob shaft is flat on top 2 A small brass screw inside the hole controls the air gas mix at the burners use a small flat head screwdriver to adjust a To decrease the flame size rotate to the left to allow more air b To increase the flame size rotate to the right to reduce the air c Make small incremental changes Figure 23 Adjust Burner Orifice 3 Replace the knob by aligning the flat part of the kno...

Страница 38: ... must be completed by a licensed plumber or gas professional 1 Unplug the burner unit 2 Shut off and disconnect the gas source from the burner unit 3 Remove the cover and grate set aside 4 Lift the front burner out and set it near the rear burner The igniter plug is attached to the burner knob Do not pull on the cable enough to unplug the igniter Figure 25 Remove Burner 5 Use a shallow 6mm socket ...

Страница 39: ... 3 8 on the other NG gas inlet regulator with 1 2 opening on each side Figure 41 right an arrow or the words IN and OUT should indicate the gas flow direction If regulator is installed the wrong way it will not work and gas won t flow Remove the old inlet and replace hand tight with the new do not overtighten Figure 26 Gas Inlets 9 Connect the gas supply per the Connection section 10 Complete a le...

Страница 40: ...f the knob and adjust the setscrew shown in Figure 28 until the flame is 1 2 to 1 high c Align the knob opening with the shaft and press the knob back into position Figure 28 Flame Adjust Setscrew 13 Replace the cooking grate and ensure the burner unit is fully seated into the grill island 14 Plug in the light power supply and resume use ...

Страница 41: ...GSL SB2B Double Side Burner Operator Manual Double Side Burner Diagram 39 Double Side Burner Diagram ...

Страница 42: ...e ORIGINAL PURCHASER S transfer of ownership of the burner unit to any other person or entity This Limited Warranty excludes and does not cover 1 oxidation rust corrosion discoloration staining or other cosmetic issues or 2 damage deterioration or warping related to or resulting from in whole or in part a failure to install and use a proper regulator for gas supply type NG or LP b severe weather c...

Страница 43: ...SE GRILLS Paradise Grills shall not be liable to the ORIGINAL PURCHASER or any other person or entity for any incidental indirect special reliance general ordinary nominal pain and suffering lost profits exemplary general punitive or consequential damages that are in any way based upon related to or arising from the burner unit either in whole or in part regardless of the legal theory on which the...

Страница 44: ...and barred To submit a warranty claim the ORIGINAL PURCHASER must submit a written description and photographs detailing the burner unit s damage or defect s along with a complete copy of the Final Sales Agreement either i via email to Warranty Claim paradisegrills com or ii via U S mail to Paradise Grills International Inc Attn Warranty Claim 640 Ocoee Business Parkway Suite 80 Ocoee Florida 3476...

Отзывы: