Attach the 15 pin interface cable to the interface ports on each amplifier. Attach the
switch control cable to the amplifiers and the switches. Ensure that the A1 labeled
connector connects to amplifier 1, the A2 labeled connector connects to amplifier 2.
DIP Switch Selections
The user configurable DIP switches have the same functions as for a stand-alone
unit. Several of the factory set DIP switches change.
System Architecture
To differentiate the amplifier as being part of a 1:1 redundant system, S6 pin-7 is set
to “ON” and S6 pin 8 is “OFF”.
Local Address
To serially communicate with the individual amplifiers as well as the system, each
amplifier is assigned a unit ID. This ID is set using pin-1 and pin-2 of S7. To desig-
nate an amplifier as unit 1, pin-1 is set to “ON”, pin-2 to “OFF”. To designate an
amplifier as unit 2, pin-1 is set to “OFF”, pin-2 to “ON”.
Front Panel Operation
The system can be controlled from the front panel of either amplifier using the key-
pad and LCD display. The LEDs on the front panels indicate the state of the specific
amplifier, refer to Table 3-1.
Operations Menu
The OPS menu has several additions for changing the system parameters.
Switch Voltage
A monitor is provided to ensure that the addi28V supply is operating cor-
rectly. This voltage is viewed on line 2 of the OPS menu
Set Switching Mode
The Switching Mode selection is added to line three of the OPS menu. When ac-
tive, the “+” or “-” keys will toggle the mode between Auto and Manual. When the
system is in Auto mode, automatic amplifier switching occurs when the on-line amp
registers a summary fault. When in Manual mode, automatic switching does not
occur, however, a system summary fault is registered. The user must manually
issue the command through the Set Standby Amp command from the front panel or
the serial port.
Set Standby Amp
This entry is added to line three of the OPS menu. When active, the “+” or “-” keys
will toggle the system standby amplifier. This command is only accepted when the
Switching Mode is set to Manual. If an amplifier has faulted when the system is in
Содержание HPAC-100-RM
Страница 2: ......
Страница 58: ...5 4 Operations Manual HPAC 100 125 150 200 250 RM SSPA 5 Performance Tests THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 64: ...A 2 Operations Manual HPAC 100 125 150 200 250 RM SSPA Appendix A THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 68: ...HPAC 100 250 doc 10 10 01 C Band SSPA Rack Mount Model HPAC 100 125 150 200 250 RM ...
Страница 70: ......
Страница 80: ...B 10 Operations Manual HPAC 100 125 150 200 250 RM SSPA Appendix B THIS PAGE INTENTIONALLY LEFT BLANK ...