3-28
Operations Manual: HPAC-100/125/150/200/250-RM SSPA
3 Operation of Stand-Alone Unit
System Summary
Response to a Report System Summary command. The Data field value indicates the
general “health” of a particular unit or the entire system.
Type:
RESPONSE
Pkt Length:
7
Destination:
M&C Address
Source:
SSPA System Address
Command:
0x90
Data:
Unit ID:
(1 byte, integer)
[ 0 | 1 | 2 | 3 ]
Summary Fault Status
(1 byte, integer)
0 = No Go
Unit or system has a summary fault.
1 = Go
Unit or system does not have a summary
fault.
Length:
9 bytes
When this response is coming from the system controller, Unit ID = 0, the “Go” status
indicates that at least one amplifier in the redundant configuration is operational. The
“No Go” status indicates that all amplifiers are faulted.
For a standalone unit, Unit ID = 1, 2, or 3, the “Go” status indicates that the amplifier is
not faulted. The “No Go” status indicates that the amplifier is faulted. This is the same
value as Unit Summary Fault in the Unit Status Response.