Operations Manual: HPAC-100/125/150/200/250-RM SSPA
3-7
3 Operation of Stand-Alone Unit
Status Menu
The Status menu displays the current settings of the amplifier. It is a monitoring tool
only and values cannot be set from it.
Line 1 displays the output power in dBm and the temperature of the hottest unit in
degrees Celsius.
Line 2 displays the attenuation level and the mute state of the amplifier.
Line 3 shows whether the control is LOC/REM and any amplifier faults. Normal opera-
tion should display “FLT: NONE”, whereas if a fault occurs then “NONE” will be replaced
by “FAULT”. A detailed description of the fault is available on line 1 of the OPS menu.
Setup Menu
The Setup menu is used to select which user selectable faults should be included in the
summary fault and also the appropriate threshold values. The summary fault of the unit
automatically includes voltage, current, and an over temperature shutdown fault. In
addition, the user can select to include Low RF Power, High RF Power, High Tempera-
ture, Auxiliary Input and High Reflected Power (optional) faults. Each of the user
configurable faults contains an ON/OFF toggle on line 2 as well as a threshold value on
line 3.
Also shown on the setup menu is the revision level of the unit software.
↓
→
←
+
−
> ops [STATUS] setup
P: 43.2 dBm
T: 35
°
C
Ctrl: LOC
Flt: NONE
Attn: 00dB
Mute: OFF
ops status [SETUP]
SUMMARY FAULT ALARM
Threshold = 37 dBm
>
Low RF Power: ON
↓
→
←
+
−
Содержание HPAC-100-RM
Страница 2: ......
Страница 58: ...5 4 Operations Manual HPAC 100 125 150 200 250 RM SSPA 5 Performance Tests THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 64: ...A 2 Operations Manual HPAC 100 125 150 200 250 RM SSPA Appendix A THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 68: ...HPAC 100 250 doc 10 10 01 C Band SSPA Rack Mount Model HPAC 100 125 150 200 250 RM ...
Страница 70: ......
Страница 80: ...B 10 Operations Manual HPAC 100 125 150 200 250 RM SSPA Appendix B THIS PAGE INTENTIONALLY LEFT BLANK ...