8
Section 4 Operating Instructions
4.1 Introduction
This sections contains the general operating instructions for Paradigm Wireless Systems
MAF 900-60S MCPA. This will help guide the user on proper operation of the MCPA.
4.2 Initial Start-Up and Operating Procedure
To perform initial start-up, proceed as follows:
1. Carefully remove MAF 900-60S MCPA series from shipping carton
2. Place MAF 900-60S MCPA into sub-rack assembly
Caution
When placing MAF 900-60S MCPA into sub-rack gently slide MCPA into matting
connector. Damage can occur to matting connector due to abrupt handling of the unit.
To ensure good performance of the unit visual matting is recommended.
Note
All RF connections to the unit will be of 50 ohm. Any changes in impedance will cause
severe mismatch and VSWR to occur. Do not operate the amplifier without a load
attached to output of sub-rack.
3. Connect all RF input and output cables to the sub-rack.
4. Ensure (Reset) switch to OFF position and source power is un-keyed or turned off.
5. C27 Vdc power source to sub-rack
6. Turn +27 Vdc to ON position. Place (Reset) to ON position.
7. Ensure sub-rack fans are working.
8. Normalize amplifier for 5 minutes in ON position. Monitor for alarms on front
panel.
9. Before turning on source power, verify RF level is set to minimum. High source
input level can damage amplifier.
10. Turn-on 1 channel from source power. Set power level.
Note
•
If operating MAF 900-60S MCPA without sub-rack, individual fans, RF
attenuation, and D-Sub connector needs to be assembled for operation.
Please contact your representative at Paradigm Wireless Systems for
information.