WARNING:

  

This Uninterruptible Power Supply contains potentially hazard-

ous voltages.  Do not attempt to disassemble the UPS beyond the battery
replacement procedure.  This UPS contains no user serviceable parts.  Re-
pairs and battery replacement must be performed by

 QUALIFIED SERVICE

PERSONNEL ONLY.

AVERTISSEMENT!  

Cet onduleur contient des tensions potentiellement

dangereuses. N'essayez pas de le démonter au-delà de la procédure de
remplacement de la batterie. L'onduleur ne contient aucune pièce réparable
par l'utilisateur. 

SEUL UN TECHNICIEN QUALIFIÉ

 est autorisé à effectuer

les réparations et le remplacement d'une batterie.

WARNING:  Qualified Service Personnel ONLY 

must perform the Installa-

tion and Servicing of these UPS systems.  MINUTEMAN accepts no liabilities
and is not limited to: injury to the Service Personnel, or damages to; the UPS,
or the connected equipment caused by the incorrect installation or servicing
of the UPS system.

AVERTISSEMENT!  Seul un technicien qualifié

 peut installer et entretenir

ces systèmes UPS. MINUTEMAN n'accepte aucune responsabilité pour, sans
s'y limiter : les blessures souffertes par le personnel de service ou les dommages
infligés à l'onduleur ou au matériel connecté, résultant d'une mauvaise installa-
tion ou d'un entretien incorrect de l'onduleur.

WARNING:

  

Risk of Electrical Shock.  Hazardous live parts inside these

power supplies are energized from the battery even when the AC input is
disconnected.

AVERTISSEMENT!  

Risque de choc électrique. Les parties actives dangereuses

à l'intérieur de ces blocs d'alimentation sont sous tension à partir de la batterie,
même lorsque l'alimentation c.a. est coupée.

ON / OFF / TEST BUTTON:  

When the UPS is connected to an AC

source and there is an acceptable AC voltage present; 

Press and then

release the On/Off/Test button during the audible alarm's first beep to
turn the UPS on.  UPS will provide an output and the load will be
powered.  Then the UPS will perform a five second self-test.  Once
the UPS has passed its self-test the UPS will be ready for normal
operation.

When the UPS is in the AC mode; Press and then release the On/
Off/Test button during the audible alarm's first beep to turn the UPS
off.

To perform a ten-second self-test:  With the UPS in the AC mode,
press and hold the On/Off/Test button until the audible alarm sounds
four beeps, and then release.  During the test, the UPS will switch to
the Battery mode, the On-Battery icon will illuminate and the audible
alarm will sound.

To de-energize the outputs of the UPS:
1.

If the UPS is on, press and release the On/Off/Test button during the aud-
ible alarm's first beep to turn the UPS off.

2.

Disconnect the UPS from the AC wall outlet.

3.

To de-energize the UPS completely, disconnect the battery.

CAUTION! 

 To reduce the risk of electrical shock in conditions where the load

equipment grounding cannot be verified, disconnect the UPS from the AC wall
outlet before installing a computer interface cable.  Reconnect the power cord
only after all signaling connections are made.

ATTENTION!

  Pour réduire le risque de choc électrique dans une situation où

il n'est pas possible de vérifier la mise à la terre du matériel de charge, il faut
d'abord débrancher l'onduleur de la prise murale c.a. avant d'installer un câble
d'interface ordinateur. Rebranchez le cordon d'alimentation uniquement après
que toutes les connexions de signalisation aient été établies.

NOTE:

  These UPSs are shipped with the batteries disconnected.  The batter-

ies must be connected before putting these UPSs into service.  Refer to Sec-
tion 3 "Installation" for connecting the batteries.

CAUTION!  

DO NOT USE THE MOUNTING BRACKETS TO LIFT THE

UPS.

  The mounting brackets are 

ONLY

 for securing the UPS to the rack.

ATTENTION!  N'UTILISEZ JAMAIS LES SUPPORTS DE MONTAGE POUR
SOULEVER L'ONDULEUR.

 Ces supports sont 

uniquement

 conçus pour

fixer l'onduleur au rack.

NOTICE!

  The output of this device is not sinusoidal.  It has a voltage total

harmonic distortion and maximum single harmonic distortion as below:

Total harmonic

PRO2000RT2U

35.6%

Model

PRO750RT2U

31.3%

PRO1000RT2U

30.3%

PRO1500RT2U

37.2%

Single harmonic

15.7%

14.5%

14.9%

18.7%

Содержание Minuteman PRO-RT 2U Series

Страница 1: ...User s Manual PRO RT 2U Series UPS Para Systems Inc 1455 Lemay Dr Carrollton TX 75007 Phone 1 972 446 7363 Fax 1 972 446 9011 Internet minutemanups com UPS Sizing sizemyups com PN 34000526 R3 ...

Страница 2: ...n 2 2 Controls and Indicators 8 3 Installation 11 4 Operation 18 5 Obtaining Service 22 6 Troubleshooting 23 7 Replacing the Battery 24 8 Specifications 28 9 Limited Product Warranty 30 A1 Declaration of Conformity 31 ...

Страница 3: ...rrectement installer le système pour atteindre son rendement maximum en toute sécurité CAUTION Connect the UPS to a two pole three wire grounded utility power AC wall outlet The receptacle must be connected to the appropriate branch protection circuit breaker or fuse Connection to any other type of recep tacle may result in a shock hazard and violate local electrical codes Do not use extension cor...

Страница 4: ...self test Once the UPS has passed its self test the UPS will be ready for normal operation When the UPS is in the AC mode Press and then release the On Off Test button during the audible alarm s first beep to turn the UPS off To perform a ten second self test With the UPS in the AC mode press and hold the On Off Test button until the audible alarm sounds four beeps and then release During the test...

Страница 5: ... prior written permission of Para Systems Given that Para Systems will continuously improve and de velop the product changes may be made to the information in this Manual at any time without obligation to notify any person of such revision or changes Para Systems will make all possible efforts to secure the accuracy and the integrity of this Manual Para Systems disclaims any kinds or forms of war ...

Страница 6: ...played and the UPS will sound a constant alarm to indicate that there is an Overload condition Battery Capacity Bar Graph Displays the amount of Battery Ca pacity available in the AC and Battery mode as 20 40 60 80 100 UPS Parameters Input Voltage and Frequency Output Voltage and Frequency Connected load KVA and KW Estimated Runtime minutes AC mode and Battery mode The Multi Function On Off Test b...

Страница 7: ...ptacles are electrically wired into two segments to support the Load Shedding Function Labeled Load 1 Load 2 7 TheAlways On Battery Backup output receptacles LabeledAlways On does not support the Load Shedding Function NOTE The locking recptacle is only on the PRO2000RT2U model 8 The option slot is for option cards 9 The rackmount brackets are for mounting the UPS to the rack 10 The RJ11 45 modula...

Страница 8: ...unstable due to the weight distribution 2 The Rackmount Configuration is complete See Connecting your Equipm ent CONNECTING THE BATTERIES QUALIFIED SERVICE PERSONNEL ONLY Please read all of the WARNINGS and CAUTIONS before attempting to con nect the batteries Use two or more people when installing the UPS the UPS is extremely heavy 1 Remove the UPS from the shipping box and place on a flat surface...

Страница 9: ...R CONFIGURATION The tower configuration allows the user to install the UPS in the up right position The tower brackets are provided with the UPS Use two or more people when installing the UPS the UPS is extremely heavy 1 Once the location of the UPS has been determined place the UPS on a flat sur face remove the rackmount brackets from the UPS and then place the tower br ackets in the desired loca...

Страница 10: ...electrical device into the output receptacles of the UPS COAX PROTECTION CONNECTION OPTIONAL Connect a cable modem CATV converter DSS receiver or DVR to the coax connectors on the rear panel of the UPS This connection will require another coax cable The cable coming from the coax service is connected to the port marked IN The equipment to be protected is connected to the port marked OUT NOTE Conne...

Страница 11: ... will blink During normal AC operation the UPS will quietly and confidently protect your system from power anomalies The UPS will charge the batteries with the UPS in the on or off position when the UPS is plugged into the wall outlet and there is an acceptable AC voltage present 90 150VAC When a blackout brownout or an overvoltage condi tion occurs the UPS will transfer to the battery mode the On...

Страница 12: ...y tests the battery s condition If the battery is weak bad or disconnected the Weak Bad Battery icon will illuminate and the Battery Capacity Bar Graph will turn off the LCD screen will display error code E06 and the audible alarm will sound three beeps every five minutes until the bat tery is either reconnected or replaced This alarm will be repeated until the batteries pass a self test It is rec...

Страница 13: ...or the UPS Check the specifications Chapter 5 Obtaining Service IF THE UPS REQUIRES SERVICE 1 Use the Troubleshooting section to eliminate obvious causes 2 Verify there are no tripped circuit breakers and that the batteries are good A tripped circuit breaker and defective batteries are the most common iss ues 3 Call your dealer for assistance If you cannot reach your dealer or if they cannot resol...

Страница 14: ...battery system can present a risk of electrical shock These batteries produce sufficient current to burn wire or tools very rapidly produc ing molten metal Observe these precautions when replacing the batteries 1 Remove watches rings or other metal objects 2 Use hand tools with insulated handles 3 Wear protective eye gear goggles rubber gloves and boots 4 Do not lay tools or other metal parts on t...

Страница 15: ...IG 2 FIG 3 7 Disconnect the battery connectors FIG 2 8 Remove the four retaining screws for the battery retaining bracket FIG 2 9 Remove the battery retaining bracket and set aside 10 Grasp the battery pull tab and gently pull the battery module out of the UPS and set aside FIG 3 NOTE DO NOT use the battery wires to pull the battery module out Use Caution the battery module is heavy 11 Slide the n...

Страница 16: ...Life 3 to 5 years Environmental factors do affect battery life High temperatures poor utility power and frequent short duration discharges have a negative impact on battery life 8 hours to 90 capacity from a full load discharge Battery Type Sealed Non Spillable Maintenance Free Value Regulated LeadAcid Runtime Half Load minutes Runtime Full Load minutes SURGE PROTECTION AND FILTERING Audible Noise...

Страница 17: ... FIT NESS FORAPARTICULAR PURPOSE Some states do not permit limitation of implied warranties therefore the aforesaid limitation s may not apply to the purchaser EXCEPT AS PROVIDED ABOVE IN NO EVENT WILL PARA SYSTEMS BE LIABLE FOR DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT EVEN IFADVISED OF THE POSSI BILITY OF SUCH DAMAGE Specifically Para Syst...

Страница 18: ...33 32 Notes Notes ...

Отзывы: