LED Keypads 7
2.3.1 Normal Mode
When no actions are being performed on the keypad, the keypad
will remain in
Normal Mode
. In
Normal Mode
the LED keypad will
illuminate:
•
The “AC” Light if power is present
•
The Numerical Symbols representing any open zones
•
The Area Symbols if any areas are armed
•
The
[
MEM
]
Symbol if any alarms have occurred
•
The
[
TRBL
]
Symbol if any troubles are occurring
•
The
[
BYP
]
Symbol if zones are bypassed and show the status
of the “Status” Light (see Figure 2-1,page 5)
2.3.2 Confidential Mode
The installer can program the keypads not to display the status
of your system automatically by changing the LED keypad from
Normal Mode
to
Confidential Mode
. In
Confidential Mode
all the
Symbols and Keypad Indicator Lights are extinguished.
Depending on how your keypad was programmed by the
installer, you must either press a button or enter your User
Access Code to activate
Normal Mode
.
2.3.3 Backlight
The illumination behind the buttons can be modified to suit your
needs.
How do I modify the Backlight?
1) Enter your
[
ACCESS
CODE
]
.
The keypad will emit a Confirmation Beep. The [
ACCESS
]
Symbol will flash.
KLEDEU03.fm Page 7 Friday, May 4, 2001 11:25 AM
Содержание Digiplex DGP-620
Страница 1: ...Digiplex LED Keypads User s Manual KLEDEU03 fm Page 1 Friday May 4 2001 11 25 AM...
Страница 2: ...KLEDEU03 fm Page 0 Friday May 4 2001 11 25 AM...
Страница 41: ...LED Keypads 39 Figure 8 1 Delayed Fire Zone KLEDEU03 fm Page 39 Friday May 4 2001 11 25 AM...
Страница 53: ...KLEDEU03 fm Page 51 Friday May 4 2001 11 25 AM...
Страница 54: ...KLEDEU03 fm Page 52 Friday May 4 2001 11 25 AM...