background image

 

 

Page 3 

the coppers (4/8 wires for RJ11/RJ45  ) one end, and terminating 
modular plug the other end.  

 
OPTIONAL USE  METHOD (PAIRED) : 

Connect one clip to a wire and connect the other clip to the other 
wire of pair(See figure 4). This method can further verify if tracing 
pair is the target by momentarily shorting the pair at trace end and 
found that the tone is stop. 

 
2.  PROBE TRACING 

  Press the round on/off spring-loaded button of the amplifier probe. 

The volume control switch can be adjusted to suit the environment. 

Do not adjust volume with sound too high for better identifying 
target pair from crosstalk pairs

 . 

  Touch the tip of the amplifier probe to the insulation of each 

suspected pair. 

  Speaker will receive tone which will be loudest on the target pair. 

  Alternative using LED as visual tracing by observing its brightness. 

Brightest LED indicate receive of tone from the target pair. 
If using in high background noise or crosstalk ( other wires in group 
also have tones). It may needs to set volume to the level which 
cancel brightness of background noise or crosstalk from LED before 
tracing. Setting done by pressing button on probe, touch the tip to 
those wires which have

 

background noise or crosstalk, and adjust 

volume down slowly from position high to low until LED brightness 
cut off or very fade. Then start  tracing

 

without adjusting volume, 

which a bright LED indicate receive of tone from the target. 

  In noisy environment such as server room,etc., earphone can be 

connected to audio jack for better hearing. 

 
B) LINE TESTING BY TONE GENERATOR 

 

IDENTIFYING PHONE TIP & RING 

(

SWITCH TO “OFF”

)

 

1.  Connect the RED clip to a wire and the BLACK clip to the other wire of 

pair. 

2.  The LED will glow “GREEN” when you connect the RED test lead to 

the RING SIDE. 

3.  The LED will glow “RED” when you connect the RED test lead to the 

TIP SIDE. 

 
 

VERIFYING PHONE LINE CONDITION 

(

SWITCH TO “OFF”

)

 

1.  Connect the RED clip to a wire and the BLACK clip to the other wire of 

pair. 

2.  Observe the LED: 

  A BRIGHT  “GREEN” or “RED” LED indicates a CLEAR line. 

  No lamp indicates a BUSY line. 

  A  BLINKING LED indicates a RINGING line. 

 

Содержание Metodo2

Страница 1: ...ply by 9V battery with an average operating life of 100 hours Audio earphone jack for operating in noisy environment such as server room etc LED for illustration of signal strength of tone receiving Figure 1 Amplifier Probe Figure 2 Tone Generator Audio jack Volume control ON OFF button LED Black Red Modular plug LED 3 position toggle switch Tone Generator Amplifier Probe must be installed 9V batt...

Страница 2: ...le solid tone can be done by slide switch on PCB inside Connection the tone generator to line pair has 2 methods OFTEN USE METHOD GROUNDED Connect red clip to a wire and connect black clip to ground or large metal part for example rack cabinet See figure 3 This method provide strongest tone and often use If connection point is RJ11 RJ45 jack please use a self made modular plug to copper adaptor Se...

Страница 3: ...es in group also have tones It may needs to set volume to the level which cancel brightness of background noise or crosstalk from LED before tracing Setting done by pressing button on probe touch the tip to those wires which have background noise or crosstalk and adjust volume down slowly from position high to low until LED brightness cut off or very fade Then start tracing without adjusting volum...

Страница 4: ...on butt set verify a continuity of the line is good All above line testing by tone generator of item B are also can be done by connecting with RJ11 modular plug instead of test clips REMARK COAX LINE CONNECTING 1 Connect red clip to outer shield of coax and black clip to ground or large metal part for grounded method tracing 2 Connect one clip to outer shield and the other clip to center conductor...