IDENTIFYING

 

PHONE LINES 

(

SWITCH TO “OFF” THEN “CONT”

)

 

1.  Dial the line to be identified. 
2.  While the line is being ring, connect the RED clip to a wire and the 

BLACK clip to the other wire of pair. 

3.  In the “OFF” position, the indicator LED will blinking “GREEN” or “RED” 

if connected to the target pair. 

4.  Further confirm by switch  to “CONT”, that will terminate the calling . 

 

 

TESTING LINE CONTINUITY

(

SWITCH TO “CONT”

)

 

1.  Connect the RED clip to a wire and the BLACK clip to the other wire of 

pair  

2.  Shorting both wires at the other end of line 
3.  A bright “GREEN” LED indicates continuity of line is good.  LED will not 

work if the line resistance exceeds 10K Ohms 

 

TESTING LINE CONTINUITY WITH BUTT SET 

(

SWITCH TO “TONE”

)

 

1.  Connect the RED clip to a wire and the BLACK clip to the other wire of 

pair. 

2.  Connect a Butt set/ Telephone Test Set in monitor mode at the other 

end of line  

3.  Reception of clear tone on butt set, verify a continuity of the line is good. 

   
  All above line testing by tone generator of item B)  are also can be done by 
    connecting with RJ11 modular plug instead of test clips. 

 

REMARK) COAX LINE CONNECTING 

1.  Connect red clip to outer shield of coax and black clip to ground

 

or 

large metal part for “grounded method tracing”. 

2.  Connect one clip to outer shield and the other clip to center 

conductor of coax for “paired method tracing” and “line testing by 
tone generator”.   

 

MAINTENANCE 

The Tone Generator and amplifier probe is maintenance free except for 
battery replacement. Below is the Instruction for Battery replacement

 

Probe Amplifier  

Remove the screw from the battery compartment, replace

 

with new 9V battery and re-assemble screw DO NOT OVERTIGHTEN. 

Tone Generator   

Separate the case by removing a screw on back side, replace with new 
9V battery and re-assemble screw DO NOT OVERTIGHTEN. 

 

Warranty 

Warranty limited solely to repairing or replacement, Warranty will not cover 
for unit that was defected by accidental, improper uses and one repaired by 
other than manufacturer’s personnel. 

Содержание Metodo2

Страница 1: ...ply by 9V battery with an average operating life of 100 hours Audio earphone jack for operating in noisy environment such as server room etc LED for illustration of signal strength of tone receiving Figure 1 Amplifier Probe Figure 2 Tone Generator Audio jack Volume control ON OFF button LED Black Red Modular plug LED 3 position toggle switch Tone Generator Amplifier Probe must be installed 9V batt...

Страница 2: ...le solid tone can be done by slide switch on PCB inside Connection the tone generator to line pair has 2 methods OFTEN USE METHOD GROUNDED Connect red clip to a wire and connect black clip to ground or large metal part for example rack cabinet See figure 3 This method provide strongest tone and often use If connection point is RJ11 RJ45 jack please use a self made modular plug to copper adaptor Se...

Страница 3: ...es in group also have tones It may needs to set volume to the level which cancel brightness of background noise or crosstalk from LED before tracing Setting done by pressing button on probe touch the tip to those wires which have background noise or crosstalk and adjust volume down slowly from position high to low until LED brightness cut off or very fade Then start tracing without adjusting volum...

Страница 4: ...on butt set verify a continuity of the line is good All above line testing by tone generator of item B are also can be done by connecting with RJ11 modular plug instead of test clips REMARK COAX LINE CONNECTING 1 Connect red clip to outer shield of coax and black clip to ground or large metal part for grounded method tracing 2 Connect one clip to outer shield and the other clip to center conductor...

Отзывы: