G. Cleaning and Maintenance
1.
Cut off the power supply before cleaning to avoid accidents.
2.
Do not use wet towel with non-corrosive cleanser to clean the module plate, the surface of
the equipment and power cord. Direct wash by water is not advised in case of any damage
of the components.
3.
When the unit is not in use, please turn off via the temperature controller and main switch.
4.
Please store the equipment in a ventilated location without corrosive gas.
H. Troubleshooting
Problem
Cause
Solution
Module plates do not heat when
the power and heating indicator
are both on.
1.
Temperature controller is
broken.
2.
At least one of heating
elements has blown.
3.
The
high
temperature
protector has activated.
1.
Replace
the
temperature
controller.
2.
Replace the heating element.
3.
Dismantle the bottom plate
and
reset
the
temperature
protector.
When the power is
on and
temperature controller is switched
on and heating indicator is on the
temperature can be not controlled.
1. Temperature controller is
broken.
1.
Replace
the
temperature
controller.
Indicator is not on when the
power is on and the heating
process is normal.
1. Indicator is broken.
1. Change temperature indicator.
The indicator does not function
when the power is on.
1.
Abnormal power supply or
cut-off power supply.
2.
Fuse is burned.
1.
Check
power
supply
and
connection
to
make
power
supply be normal.
2.
Change fuse.
The aforementioned problems are just for reference. If a fault occurs, please
cease using and consult professional technicians for advice and repair.