GB310 Service Manual
1
PANTECH
6.1.2 Oscillation CHECK
1. Check to see if U101 No. A3 and B3 pin is oscillated(32.768KHz) : CP107
NO Check R141 and then replace X101
2. Check to see if U101.L12 pin Master Clock(13MHz). : CP108
NO Check TP116, C137 pin and then check the PCB pattern, soldering
CP107
CP107
CP108
CP108
Содержание GB310
Страница 28: ...GB310 Service Manual 1 PANTECH 8 Check to see if U103 K5 J5 pin and C152 C153 is 2 8V_M CP105 CP105 CP105...
Страница 29: ...GB310 Service Manual 1 PANTECH 9 Check to ses if PAD1 pin R177and D120 C213 pin is 2 8V_EXT CP106 CP106...
Страница 42: ...GB310 Service Manual 1 PANTECH CP128 CP129 CP130...