background image

 

Instruction Manual VET LIFT 

 

Page 21 of 27  

Version 2.02 

 

Содержание VET LIFT 7H9.6P1

Страница 1: ...nstruction Manual VET LIFT Page 1 of 27 Version 2 02 VET LIFT INSTRUCTION MANUAL For optimal and safe handling of the product thoroughly reading and following the present Instruction Manual is essential ...

Страница 2: ...al 0 stainless steel 1 synthetic Hydraulic version for VET LIFT with integrated scale not available Hydraulic version for VET LIFT STAINLESS STEEL not available Congratulations on your purchase of the present veterinary treatment and surgery equipment We are very delighted that you have made the decision to select a panno med product During the development and manufacturing of our products we plac...

Страница 3: ...ixed version with one sided castors 9 Power supply electric version with power cord 9 Charging the table battery powered version 10 Weighing functionality version with integrated scale 11 Error handling Troubleshooting 17 Cleaning and disinfection instructions 18 Cleaning stainless steel top 18 Cleaning synthetic top 19 Special cleaning and care instructions STAINLESS STEEL versions 20 Supplementa...

Страница 4: ... optimally and safely Hence panno med cannot be held liable for any damage or injury resulting from improper or incorrect use of the product The maintenance and care procedures for the product are designed to ensure that it achieves a long lifespan It is therefore essential that all the operating personnel are informed about the proper handling of the product Thus the entire operating personnel mu...

Страница 5: ...2 kg 126 159 lbs Gross weight incl packaging ca 76 91 kg 168 201 lbs Weight depending on width accessories and other options Height adjustment with integrated scale from ca 335 1045 mm 13 2 41 2 inch Packaging dimensions 1350 x 650 x 470 mm 53 1 x 25 6 x 18 5 inch 1350 x 650 x 700 mm with integrated scale 53 1 x 25 6 x 27 6 inch Voltage electrical version 230V 50 60Hz max 1 5A valid for EU CH UK A...

Страница 6: ...e of the base frame of your product using the two screws included in the scope of delivery as well as the Allen key At first the two screws on the selected longitudinal side of the base frame must be unscrewed Then the console is mounted together with the foot switch being threaded through the central hole For this purpose the console including the foot switch is attached and screwed to the base o...

Страница 7: ...connection or by a rechargeable battery Pressing the left button on the foot switch raises the table or initiates an upward movement In the opposite case pressing the right button lowers the table or initiates a downward movement The button must remain pressed until the desired height is attained Releasing this button brings the table plate to a standstill at the desired height Height adjustment h...

Страница 8: ...he top can be held in any desired position up to max 11 and releasing the flap keeps it in the respective position As a result this mechanism allows convenient single hand operation Tilting as well as tilting back in the opposite direction is performed by actuating and holding the indicated flap upwards Maneuverability movable version with double castors The product is equipped with four independe...

Страница 9: ...nter of gravity should be slightly moved by lifting the product onto the castors located on two legs and the device can be easily rolled away In this case the user is advised to stand on the side of the fixed part of the table and when the table is lifted to push it in the desired direction Once the table has reached the designated position it is necessary to set the table down again so that an ev...

Страница 10: ...he battery is located on the front side of the tables chassis near the bottom and can be easily disconnected from the table by pressing the tab on the black edge of the battery Reinserting the battery is done by sliding the battery into the housing until an audible click is heard and the battery is thus securely locked in place and connected to the product In order to achieve a long battery lifesp...

Страница 11: ... useful in this case This battery is fully charged when the LED light on the charger goes out Please note that the number of possible strokes with one battery charge depends on the respective load therefore more load means fewer strokes Weighing functionality version with integrated scale In case you have chosen a model with integrated scale the following technical specifications are additionally ...

Страница 12: ...pened Thereafter a set consisting of 4 pieces of AA batteries is inserted After closing the flap on the rear side of the display the installation of the batteries is completed Lastly the scale display must be inserted into the designated rack on the long side of the table respectively on the right edge of the scale In particular pay attention to the two clamps on the left and right sides of the ra...

Страница 13: ...omatic weighing system Do not impose a permanent load on the weighing plate Do not use the scale for dynamic weighing Avoid shocks and overloads at all times Under no circumstances should the product be operated in rooms with potentially explosive atmospheres Do not modify the construction of the scale Before plugging in the power cord ensure that the voltage indicated on the power supply is ident...

Страница 14: ...Instruction Manual VET LIFT Page 14 of 27 Version 2 02 ...

Страница 15: ...Instruction Manual VET LIFT Page 15 of 27 Version 2 02 ...

Страница 16: ...Instruction Manual VET LIFT Page 16 of 27 Version 2 02 ...

Страница 17: ...h 14 of the product in question which is located on the type plate Potential error Recommended course of action At least one electric actuator does not work o Check if the battery if applicable is inserted as well as whether the electrical power supply to the product is provided o Ensure that the battery is fully charged or that the socket through which you want to supply electrical power to the p...

Страница 18: ...ake sure to always read the product information and observe the instructions for the respective cleaning products and disinfectants The manufacturer cannot be held liable for damage injuries and impairments which are the result of improper use of cleaning products or disinfectants Attention The product is NOT suitable for automatic washes and bed sterilizers The use of a high pressure cleaner is a...

Страница 19: ... The use of additional protective coating in the form of varnish or paint is also strongly discouraged Engravings of names or other carved information on the stainless steel plate will immediately lead to surface corrosion New stainless steel table tops usually have a flawless surface Only on a brand new table top you will be able to notice a scratch immediately However it should be mentioned at t...

Страница 20: ...urface with clean water Afterwards the surface of the frame should be wiped dry with a soft cloth Avoid extended contact of halogen containing substances chlorine bromine iodine and thiocyanate with the stainless steel surface Prolonged contact or drying of salty solutions may also cause discoloration or corrosion The use of various PVC plastic mats as underlays is also not recommended Heat exposu...

Страница 21: ...Instruction Manual VET LIFT Page 21 of 27 Version 2 02 ...

Страница 22: ...Instruction Manual VET LIFT Page 22 of 27 Version 2 02 ...

Страница 23: ...g aspects 1 Comprehensive visual and functional test a Visual inspection All welding seams for cracks Surface damages Damages to the table top All cables bruises abrasions exposed wiring Visual inspection for leak tightness of hydraulics Hinges and swivels Safety locks circlip screws star lock on all swivel joints hinges and motor suspensions Visual inspection for completeness and damage of the pl...

Страница 24: ... product without prior permission from the manufacturer Any modification may result in unpredictable and unanticipated malfunctions and thus in damage or injury to the patient The manufacturer is not liable for any damage or injury caused by modifications to the product and or the use of non original spare parts or accessories without the prior knowledge and written authorization of panno med ...

Страница 25: ... Tilting stainless steel dish with grad 602 607 OP rail extension 200 mm pair 602 610 Instrument tray 300x200 mm 602 611 Arm rest for ophthalmology 602 614 Top extension 500x300 mm 602 615 Top extension 300x300 mm 602 616 Holder with eyelets 600 mm width 602 619 Elbow pad 602 630 Belt with tension clamps 602 632 Limb holder 602 633 Ultrasound table with triangle cutout 602 640 1 Lateral positioner...

Страница 26: ...ration of the device 5 The product may only be operated by properly instructed personnel 6 Any adjustment of the product may not be performed by the patient 7 Users are responsible for ensuring that the weight is evenly distributed across the product Punctual loading must be avoided by all means 8 The usage of other accessories which are not explicitly approved by panno med for the intended purpos...

Страница 27: ...ential to ensure that loads are distributed evenly over the table surface at all times High point loads must be strictly avoided Product warranty panno med provides a warranty for the proper functioning of the product from the date of sale up to 24 months The buyer must notify the manufacturer of any damage under warranty immediately The warranty is valid only upon submission of the original invoi...

Отзывы: