background image

 

Instruction Manual ECO LIFT 

 

Page 4 of 32  

Version 2.03 

Scope of application 

 
According to its specifications, options and accessories, the present equipment is intended 
for  exclusive  use  in  veterinary  examinations,  treatments  as  well  as  surgeries  within  a 
veterinary clinic, veterinary practice, or other veterinary facilities. 
 

Intended purpose of Instruction Manual 

 
This Instruction Manual is intended to introduce you to the use, maintenance, servicing, and 
safety of your new, veterinary device. Another purpose of these operating instructions is to 
provide you with a clear and transparent overview of the functions and technical aspects of 
the equipment. We strongly recommend that you read this document carefully and follow 
the  recommendations  thoroughly  in  order  to  use  your  new  device  optimally  and  safely. 
Hence, 

panno-med

 cannot be held liable for any damage or injury resulting from improper 

or incorrect use of the product. 
 
The maintenance and care procedures for the product are designed to ensure that it 
achieves a long lifespan.  
 
It is therefore essential that all the operating personnel are informed about the proper 
handling of the product. Thus, the entire operating personnel must have access to this 
documentation and be informed about the proper handling of the product and the risks 
associated with its utilization. Furthermore, the product may only be handled by qualified 
personnel who have been appropriately trained about the risks associated with improper 
use. 
 
The manufacturer reserves the right to change the information in this document without 
prior notice, should it appear necessary from our point of view. Any complete or partial 
disclosure or reproduction of this Instruction Manual is not permitted without the explicit 
authorization of 

panno-med

 
 

Содержание ECO LIFT 6H1.6P0.CCCC

Страница 1: ...struction Manual ECO LIFT Page 1 of 32 Version 2 03 ECO LIFT INSTRUCTION MANUAL For optimal and safe handling of the product thoroughly reading and following the present Instruction Manual is essentia...

Страница 2: ...nfortunately not offered for the EMEA and APAC regions Congratulations on your purchase of the present veterinary treatment and surgery equipment We are very delighted that you have made the decision...

Страница 3: ...nt hydraulic version 13 Maneuverability optional castors as accessory 14 Adjustment of tilting mechanism 15 Adjustment of V Top mechanism for version with V Top 16 Version with heated top 17 Usage of...

Страница 4: ...optimally and safely Hence panno med cannot be held liable for any damage or injury resulting from improper or incorrect use of the product The maintenance and care procedures for the product are desi...

Страница 5: ...ibution Maximum longitudinal adjustment 80 Maximum V Top adjustment ca 45 per side V Top total ca 90 Net weight ca 54 72 kg 119 159 lbs Gross weight incl packaging ca 72 90 kg 159 198 lbs Weight depen...

Страница 6: ...n the following equipment must be made available as well as prepared in order to be able to execute the described steps Allen key 5mm should already be contained in the scope of delivery Allen key 6mm...

Страница 7: ...f 32 Version 2 03 Subsequently the rods are also threaded through at the passages of the respective clamping lever Finally the supplied plastic buffers are placed on the rods and screwed in place with...

Страница 8: ...ecessary to screw the tube holder to the center strand of the V Top frame at the points shown above For this purpose 2 pcs of M6 screws and the corresponding washers intermediate layer are used Please...

Страница 9: ...n screwed on condition These must be unscrewed from the table top accordingly before carrying out the assembly steps described in this context To stabilize and fix the rails tighten the screws accordi...

Страница 10: ...nd secured in order to provide convenient access to the screw points of the table for the following assembly steps Hence the table top is required to be initially placed upon the column as well as its...

Страница 11: ...t Lastly to stabilize and fix the entire table top and base connection tighten the mounted screws accordingly so that no more shaking of the parts is possible However please also make sure not to tigh...

Страница 12: ...ber legs were previously unscrewed using the enclosed Allen key see picture documentation below Please be careful not to overtighten the screws as otherwise the screws or the table may be damaged Make...

Страница 13: ...ressing the left button on the foot switch raises the table or initiates an upward movement In the opposite case pressing the right button lowers the table or initiates a downward movement The button...

Страница 14: ...install retroactively optimal maneuverability of the table especially in narrow and angular environments should be ensured Each castor can be locked individually and separately For this purpose the le...

Страница 15: ...such that the table top can now be maneuvered or freely adjusted within the tilting movement When the clamping lever is loosened the operator is able to move the plate to the desired tilting or horizo...

Страница 16: ...pective table top half as well as for the V top adjustment and explicitly NOT the clamping lever described in the previous chapter for the adjustment tilt of the entire table top Consequently if the p...

Страница 17: ...e clamping lever to the vertical position for locking the table top half at the new position Version with heated top The veterinary treatment and surgery table ECO LIFT with heatable stainless steel t...

Страница 18: ...the control of the heating has already stopped operation There may be a follow up or reheating of up to 3 5 C depending on the environmental conditions The longer the system is in operation the smalle...

Страница 19: ...mum temperature as well as changing the applicable temperature unit please follow the steps described below in detail In this context also consider the photo documentation provided hereafter for a bet...

Страница 20: ...emperature unit and maximum temperature should already have been considered and accepted by the heating unit Usage of tie down cleat accessory part In case any tie down cleats or similar accessories h...

Страница 21: ...xture provided for this purpose on the front side of the product as shown in the illustration to the right Removing the drain gutter from the fixture can also be done manually by pulling it out and li...

Страница 22: ...14 of the product in question which is located on the type plate Potential error Recommended course of action At least one electric actuator does not work o Check if the battery if applicable is inse...

Страница 23: ...ke sure to always read the product information and observe the instructions for the respective cleaning products and disinfectants The manufacturer cannot be held liable for damage injuries and impair...

Страница 24: ...The use of additional protective coating in the form of varnish or paint is also strongly discouraged Engravings of names or other carved information on the stainless steel plate will immediately lead...

Страница 25: ...cleaning recommendations for powder coated surfaces To ensure a long lifespan for your product the use of proper cleaning products for powder coated materials is strongly recommended Follow the instru...

Страница 26: ...Instruction Manual ECO LIFT Page 26 of 32 Version 2 03...

Страница 27: ...Instruction Manual ECO LIFT Page 27 of 32 Version 2 03...

Страница 28: ...aspects 1 Comprehensive visual and functional test a Visual inspection All welding seams for cracks Surface damages Damages to the table top All cables bruises abrasions exposed wiring Visual inspect...

Страница 29: ...product without prior permission from the manufacturer Any modification may result in unpredictable and unanticipated malfunctions and thus in damage or injury to the patient The manufacturer is not l...

Страница 30: ...ess steel dish with grad 602 607 OP rail extension 200 mm pair 602 610 Instrument tray 300x200 mm 602 611 Arm rest for ophthalmology 602 614 Top extension 500x300 mm 602 615 Top extension 300x300 mm 6...

Страница 31: ...ation of the device 5 The product may only be operated by properly instructed personnel 6 Any adjustment of the product may not be performed by the patient 7 Users are responsible for ensuring that th...

Страница 32: ...tial to ensure that loads are distributed evenly over the table surface at all times High point loads must be strictly avoided Product warranty panno med provides a warranty for the proper functioning...

Отзывы: