5) Electrical Hook-Up
CIRCUIT DIAGRAM 102- 08- 07 SEE PAGE 8
The HMI- Projector BP 12 Platin operated by hte ballast BU 12 K (Order Code
19214). The lamp current is limited to 84A by a built in inductor. Therefore an
electrical modification of the lamp current (dimming) is impossible.
In the ballast are also built in:
Compensation inductors, main contactor (interrupting the power supply when the
projector is open), ON- OFF- button, main fuses, thermical overload-switch for
ignition.
5.1) Main Connection
The main connection cable (3x 16 mm², length 1,3 m, free ends, L, N, PE) has to be
connected to a 220 / 240V / 50 Hz or a 208 / 220V / 60Hz supplly; power
consumption 74A.
For rental purposes only: CEE-plug 125A 220-250V is mounted
ATTETION! Note the power rating plates when you use a combination of various
types of ballast, because of different production types (voltage!).
5.2) Connection Cable Ballast - Projector
POSITION NUMBERS SEE PAGE 4
For the connection of the ballast with the projector a 7 pole control cable and a 4
pole supplying cable are necessary; Standard length: 3m (can be extended however
at will – for extreme cable lengths examine the cable diameters!) Both cables are
fixed on the ballast, the connection with the projector is established by using plugs.
(projector-control housing pos. 5 and pos. 6). Turning on the projector may be
operated from the projector or from the ballast. So it is possible to get the ballast into
a greater distance to the projector.
5.3) Remote Ignition - DMX 512
POSITION NUMBERS SEE PAGE 4
For ignition and shutdown of the projector by DMX 512 remote signal the projector is
equipped with a relais print inside and a remote plug outside (Ignition Socket pos. 8).
Additional the optional available Universal DMX 512 Interface and the ignition cable
are necessary (for further information see manual of the “Universal DMX 512
Interface”)