3.) Construction
3.1) Mechanical Construction of the Projector
The Aluminium housing is mounted in a stable, mobile undercarriage. Once the unit
is in place, the front casters may be lifted from the floor with the two support
spindles, fixing the unit in position. The hand wheel for height adjustment may be
found at the rear of the projector. The slide carrier may be rotated up to 90 degrees
by loosening two locking screws and turnung the projector head into any position.
The 24cm by 24cm slide may be positioned exactly by turning the adjustment screw
on the slide carrier. The slide carrier is fixed in accurate position by means of the
spring loaded locking pin. Lifting the ball knob enables the moving of the slide into
the new position, where it locks into position automatically.
4) Operating Reference
4.1) Inserting the HMI- Lamp
a) Disconnect power from the projector.
b) Open the left and right lamp access
cover (the safety switches on both
sides
prevent from starting up
the projector
with open cover).
c) Insert the lamp through one housing
opening and put it onto the two open
heat sink clamps. For some position
of the lamp/mirror slide (see page 11)
the inserting has to be in the way as
it is described on the figure beside.
Move it at last to the stop position of
the right socket stand.
ATTENTION:
ۥ
Do not touch the quartz envelope of
the lamp with your fingers during
installation. Finger prints can be
burned in!!
€‚
Position the lamp such that the fill
port is in the direction of the
reflector.
€ƒ
Lamp must be positioned along the
optical axis, symmetrically in the heat sink clamps (
oriented to the right stop position
).
d) Close the heat sink clamps by turning the star-handle. Take care, that no torsion
or bending forces are transmitted to the quartz glass body of the lamp.
e) Mount the cables on the provided cable support point.
ATTENTION:
Before you close the projector lamp access cover, control the good
fastening of all connections!