5

2.3) Ballast

Control Panel on the Ballast

1

Source Power Signal Lamp

Lights up, when the ballast is connected on primary circuit.

2

ON- button (green)

Short pressing the ON-button causes operating the main contactor, closing the 
ignition circuit and igniting the HMI-lamp by high voltage.

3

OFF- button (red)

The  lamp  source  will  be  roken.  For  re-ignition  we  recommend  to  enable  the 
equipment  to  cool  down  some  minutes.  (Hot  restrike  is  possible,  but  shortens 
the lamp lifetime).

4

Remoteswithch/ Ground Check Button

Position  left  (switch  function):  Remoteposition:  ignition  of  the  projector 
occurs automatically by powering up the equipment.
Position  right  (bottom  function):  with  correct  polarity  and  intact  earth  the 
beside-lying, yellow indicator light (5) is lit up.

5

Grounding indicator light

6

Main safety device

1 automatic circuit braker, 2 pole

7

Overload protection

8

Control cable

connection ballast – projector control panel Pos. 5

9

Supplying cable

connection ballast – projector control panel Pos. 6

10

Direct line cable

3x 6 mm², 2m long, free ends.

€•‚ƒ

IMPORTANT REMARK

208/220/240V-50/60Hz

BU12K

IP32

WICHTIGER H I N W E I S

Protective system

Schutzart

Max. environment temp.

Max. Umgebungstemp.

Rated volt.:

Nennspg.:

Type

19214

Order Code

Weight

Gewicht

Rated cap.

Nennleistung

Serial No.

Serien Nr.:

40°C

115kg

Best. Nr.

Содержание BP12

Страница 1: ...instruction manual High performance HMI Projector BP 12 Platin Order Code 22207...

Страница 2: ...onstruction of the Projector 6 4 Operating Reference 6 4 1 Inserting the HMI Lamp 6 5 Electrical Hook Up 7 5 1 Main Connection 7 5 2 Connecting Cable Ballast Projector 7 5 3 Remote Ignition DMX 512 7...

Страница 3: ...1 1 High Performance HMI Projector BP 12 Platin II 1 2 Ballast IMPORTANT REMARK 208 220 240V 50 60Hz BU12K IP32 WICHTIGER HINWEIS Protectivesystem Schutzart Max environmenttemp Max Umgebungstemp Rated...

Страница 4: ...tion Drawing 2 1 HMI Projector BP 12 Platin II with High Performance Fan LEGEND 1 Support Spindle 2 Horizontal Adjust 3 Height Adjust 4 Locking Screws 5 Housing Cover 6 Lamp Covers 7 Slide Carrier 8 S...

Страница 5: ...2 Control Panel on the Projector LEGEND 1 Source Power Signal Lamp 2 ON Push button green 3 OFF Push button red 4 Hour Counter 5 Connector for Control Cable 6 Connector for Main Power 7 Rceptables fo...

Страница 6: ...Position left switch function Remoteposition ignition of the projector occurs automatically by powering up the equipment Position right bottom function with correct polarity and intact earth the besid...

Страница 7: ...the HMI Lamp a Disconnect power from the projector b Open the left and right lamp access cover the safety switches on both sides prevent from starting up the projector with open cover c Insert the la...

Страница 8: ...f various types of ballast because of different production types voltage 5 2 Connection Cable Ballast Projector POSITION NUMBERS SEE PAGE 4 For the connection of the ballast with the projector a 7 pol...

Страница 9: ...High Performance HMI Projector BP 12 Platin II PANI Projection and Lighting Vertriebs GmbH 8 6 Circuit Diagram Drawing No 102 08 04 c...

Страница 10: ...us position is fixed by means of the two knurled nuts on either side of the projection objective NOTE The projection objectives 11 and 13 5 cm have a limited object field so they are suggested under r...

Страница 11: ...projection distance measured from the middle of the objective lens O object size i e the used slide format used slide format O 23 cm for glass slide 21 5 cm for filmholder Z ZOOM Objektiv Endposition...

Страница 12: ...125 cm PC 320 mm G 707 G 24 0034 The lamp mirror slide may be deadjusted from the standard position for some objectives to get better light output and light homogenity Therefore ulosen the two screws...

Страница 13: ...f 60 cm 320 mm multicoated G 705 G 12411 Interchangable Condenser Lens f 80 cm bis f 125 cm 320 mm multicoated G 707 G 12412 Grey Scale Shutter G 405 PCS III DMX with processor control for grey scale...

Страница 14: ...unpacked packed 124 kg 180 kg Carton Dimensions Bx Hx T 120x 84x 171 cm 1 73 m3 Ballast Supply Voltage 220 240V 50 Hz 208 220V 60Hz Supply Current 74 A Circuit Rating 100 A Weight unpacked packed 120...

Страница 15: ...ide of Cover Base 11 0094 2 Double Louvers left right 11 0069 2 Safety Switch 90 0015 2 Support Bracket for Control Box 11 0236 1 Objective Support Brackets 21 0057 4 Optical Section Heat Guard 11 009...

Страница 16: ...s 21 0061 2 Fluted Grip Bolts M6 50 21 0033 2 Hand Wheel Undercarriage 21 0062 1 Lock Bolt with Slot Head and Circlip 21 0142 2 Catch Lower Part 21 0143 2 Elektrical Material Igniter 22 0035 1 Igniter...

Страница 17: ...mp 88530192 1 15 OFF Push Button red 88402350 1 15 Contact 88402368 1 15 Socket 88402362 1 16 Control Lamp 88530192 1 16 Internal Panel 71011949 1 17 Knob 88402360 1 17 Commutator 88402361 1 17 Contac...

Отзывы: