Polar Bear East/West 10 Degree Installation Manual
9910022 Rev A
10
Figure 6 Completed Support Assembly Middle
10.
Place ballast on each support based on Ballast Layout Drawing. Each Support will accommodate
up to six Solid Cap Concrete blocks as ballast (not provided). Each block has nominal dimensions
of 4” x 8” x 16” and nominal weight of 26 lb. (11.8 kg). Blocks of various weights may be used in
advance consultation with PanelClaw’s engineering department. Various possible Ballast Block
configurations are shown below (
Note:
Blocks should not be stacked on top of each other.
Position 1 (Standard or Multi-
piece Claws) or 2 (Long Claw) on
High Side
Position “A” (Standard
or Multi-piece Claws )
or “B” (Long Claw)
(Note Support
Orientation)
Position “D”
(Note Support
Orientation)
Position “D”
(Note Support Orientation)
Wes
t