Panduit PN380 Скачать руководство пользователя страница 7

PANDUIT

 DPoE Power System User’s Guide 

 

Issue 1.0 

 

 

Part Number: PN380 

 

 

Table 1: DPoE Power Components Available from 

PANDUIT

 Corporation 

 

PANDUIT

 Part Number 

Description 

Individual power supply 

DPoEPWRB120 

Individual power supply - 120 watt power 
supply – 48 volt output 

DPoEPWRCM Managed 

power 

chassis - supports 3 rectifiers 

- equipped with Network Interface Card  

DPoEPWRCU Unmanaged 

power chassis - supports 3 

rectifiers - does not include Network Interface 
Card.  

DPoEPWRR500 

500 watt rectifier for use in either 
DPoEPWRCM or DPoEPWRCU chassis 

DPoEPWRR1250 

1250 watt rectifier for use in either 
DPoEPWRCM or DPoEPWRCU chassis 

DPoEPWRF10 

10 amp fuse (package of 10) 

DPoEPWRNIC 

Network Interface Card 

CORD-A 

Power cord for Australia 

CORD-E 

Power cord for Europe 

CORD-S 

Power cord for USA 

DPoE Power System 

CORD-U 

Power cord for the U.K. 

 

INSTALLATION 

General Practices 

 
Observe all local and national electrical, environmental, and workplace codes. 
 
Each chassis should be fed from a dedicated AC branch circuit of a TN or IT power system. 
 

CAUTION: 

The plug ends on the power cords used for the AC connections are 
considered to be the primary disconnect means.  Reasonable access must 
be given to the plug and receptacle area.  The receptacle must be fed with 
a breaker or fuse according to 

Table 4: Recommended AC Circuit Breaker 

and Wire Sizes

 
Use single hole, Underwriters Laboratory (U.L.) listed lugs for the bulk DC connection to prevent lug 
rotation and inadvertent contact with other circuits.  Terminal strip connections use compression screws. 
 
Class 1 wire is recommended for all DC connections.   
 
Minimum wire sizes for protected and unprotected circuits are shown in 

Table 5: Minimum Recommended 

DC AWG for 90° C Cabling for Unprotected Outputs

 , respectively.  In practice, loop voltage drop 

considerations will usually dictate larger than minimum safe wire size.  
 
For connection and mounting torque requirements see 

Table 6: Recommended Torque Settings

 

PANDUIT

 Corp. does not recommend shipping the chassis with the rectifiers installed.  Rectifiers should 

be shipped in their separate boxes. 

 

 

 

 

2

 

 

Содержание PN380

Страница 1: ...DPoE Power System User s Guide Issue 1 0 Part Number PN380 February 2005 2005 PANDUIT Corp All Rights reserved www panduit com...

Страница 2: ...lies with Part 15 of FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including i...

Страница 3: ...implied PANDUIT Corp specifically disclaims the implied warranties of merchantability and fitness for a particular purpose The remedies provided herein are Buyer s sole and exclusive remedies PANDUIT...

Страница 4: ...rt Circuit and Current Limit 12 Troubleshooting 12 NIC Information 12 NIC Card Settings 13 Figures Figure 1 Individual AC Feed Wiring Architecture 4 Figure 2 DC Wire Diagram 5 Figure 3 Connecting to a...

Страница 5: ...on 3 Table 4 Recommended AC Circuit Breaker and Wire Sizes 4 Table 5 Minimum Recommended DC AWG for 90 C Cabling for Unprotected Outputs 7 Table 6 Recommended Torque Settings 7 Table 7 PANDUIT Corpora...

Страница 6: ...pport all the Powered Devices PD connected to the panel In these cases or in cases of multiple DPoE Power Patch Panels a larger power system is often required One option is to use the PANDUIT DPoE Pow...

Страница 7: ...ch chassis should be fed from a dedicated AC branch circuit of a TN or IT power system CAUTION The plug ends on the power cords used for the AC connections are considered to be the primary disconnect...

Страница 8: ...s of 10 from PANDUIT part number DPoEPWRF10 Fuses are also available from Littelfuse and Bussman Their part numbers are as follows Littelfuse 481 series 10 Amp fuse part number 0481010 Bussman Fast Ac...

Страница 9: ...5 14 DC Output Wiring Sizing There are two main considerations for sizing DC wire ampacity and voltage drop Ampacity refers to the safe current carrying level as specified by U S based organizations s...

Страница 10: ...rews The bulk DC connection may be used as a battery input or as an unfused bulk output The connections require a terminal lug 1 4 single hole lug with a max tongue width of 0 63 or less Size wires ba...

Страница 11: ...e included power harness has two wires for the A feed power only pins 1 2 The DPoE Power Patch Panel supports an optional redundant B feed power option but the terminals and wire leads are not attache...

Страница 12: ...with a minimum number of commonly available tools 1 2 flat blade and Phillips head screwdrivers Torque wrench 7 16 socket drive Wire and cable strippers PANDUIT part number CT 100 Wire and cable crimp...

Страница 13: ...ng boxes until the chassis wiring is complete Power Plant Mounting and Wiring WARNING Ensure all AC and DC power sources are off and disconnected Mechanical Mounting The DPoE Power System chassis is i...

Страница 14: ...wer System User s Guide Issue 1 0 Part Number PN380 IEC320 AC cord Cord Bracket Securing Screw Figure 5 Cord Bracket Figure 6 Chassis Rear View AC Connections 4 40 Screws Figure 7 Securing Cord Bracke...

Страница 15: ...C connection requires properly crimped terminal lugs 1 4 single hole lug with a max tongue width of 0 63 or less Terminal lugs such as PANDUIT part number LCA4 14 L for use with 3 or 4 AWG stranded wi...

Страница 16: ...lease the latch handle Pull the latch handle until the rectifier clears the rear connector on the chassis then gently slide it out of the rear connector With the latch handle open on the replacement r...

Страница 17: ...latched into their respective slots Make sure all power and signal connectors are properly mated Table 8 Troubleshooting Alarm Problem Possible Solution DC OK LED is extinguished This rectifier has s...

Страница 18: ...Power System EMS Webpage via IPSetup exe on the CD provided with the chassis DPoEPWRCM only The NIC card will also work with Telnet or SNMP NIC Card Settings The NIC card comes equipped with the follo...

Страница 19: ...ature sensing device to use for battery temperature compensation Internal sensor or external temperature probes The controller will autosense when an external probe is attached and automatically adjus...

Страница 20: ...t Number PN380 15 Parameter Description Default Setting High temperature alarm release NIC Card only The temperature value at which the controller will release a HIGH TEMP alarm For systems using the...

Отзывы: