background image

INSTALLATION INSTRUCTIONS     CM310

For Technical Support: www.panduit.com/resources/install_maintain.asp

Page 5 of 8

3.1 Install Ceiling Mount Brackets against side wall of the 

enclosure with the flanged edge facing away from the 
enclosure. (see figure 3) The top of the flanged edge 
should be even with the enclosure door.

3.2 Fasten the bracket to the base of the enclosure using 

four of the supplied #6-32 Screws.

3.3 Repeat steps for remaining 3 Ceiling Mount Brackets.

Step 3: Install Ceiling Mount Brackets

3

4.1 When the enclosure will be mounted in a suspended 

ceiling, a square hole that is approximately 12 1/2" x 12 
1/2" must be cut in the ceiling tile.

4.2

It is important that the hole be no smaller than 12 1/4" 
x 12 1/4" and no larger than 12 3/4" x 12 3/4". This 
will ease installation and prevent visible gaps around 
the enclosure once installed.

Note: The bottom edges of the assembled enclosure 

brackets can be used as a guide to trace the square 
hole size onto the ceiling tile.

Step 4: Prepare Ceiling Tile

12.5"

12.5"

12.5"

12.5"

4

Option A

Option B

 

PANDUIT  Part #: PZWIFICB - PanZone Wireless Access Point

5

3/8” dia hanger wire
mounting holes
(8 places)

Step 5: Install Enclosure to Ceiling

5.1

Hanger wire should be used to hang the enclosure 
within a suspended ceiling. Important: Verify hanger 
wire meets local building code. Weight of enclosure 
and WAP does not exceed 10 lbs.

5.2

Observe how the hanger wire used to hold the ceiling 
support grid is secured to the building structure. 

5.3

Remove one tile adjacent to the tile the enclosure will 
be mounted in.

5.4

Secure four pieces of hanger wire (not included) to the 
building structure. The hanger wire length will be 
determined by the installer based on the building 
structure dimensions above the suspended ceiling. 
Extend the length of the hanger wire beyond the 
surface of the ceiling by at least 6".

5.5

Add the cut ceiling tile back to the ceiling support grid.

5.6

Pull one of the four pieces of hanger wire to one corner 
of the square opening in the ceiling tile. Pre-bend the 
hanger wire at a 90° angle approximately 2 1/2" above 
the surface of the ceiling tile. Repeat this step for the 
remaining 3 hanger wires measuring to the three 
remaining corners of the square opening.

5.7

Insert the enclosure into the cut ceiling tile opening.

5.8

While holding the enclosure flush with the surface of 
the ceiling tile, route the hanger wire through one of the 
eight 3/8" dia hanger wire mounting holes and bend up. 
Pull the wire upward until the enclosure is flush with the 

ceiling tile. Repeat this step using the three remaining 
hanger wires to secure the three remaining corners of 
the enclosure.

5.9

Visually inspect the edges of the enclosure to verify no 
gaps exist between the mounting brackets and surface of 
the ceiling tile. If gaps exist, pull the hanger wire upward 
until the enclosure is tight against the ceiling tile.

5.10 To secure the enclosure, wrap each hanger wire tightly 

around itself a minimum of three times.

5.11 Replace the adjacent ceiling tile.

                             Ceiling Bracket Kit (sold separately)

Содержание PANZONE PZWIFIEW

Страница 1: ...atch Cord PANDUIT Part No UTPCH2 1 Cat5e Jack Module PANDUIT Part No CJ5E88TWH 1 Foam Retention Plate 1 Key PZWIFIEW Keyed Knockout Slots for Wall Brackets for Fire Resistant Foam Mount Application 2...

Страница 2: ...he installation and configuration guidelines provided by the manufacturer of the wireless access point to determine the optimum enclosure installation location and antenna configuration Please read th...

Страница 3: ...eard Lightly pull the WAP in the opposite direction to verify that it is properly locked into place Step 5 Install Wireless Access Point 5a 5b Cisco Supplied Mounting Plate 6 32x1 4 Flat Head Screws W...

Страница 4: ...uit Supplied Mounting Bracket 1 1 Remove knockouts in desired cable entry location For Conduit Remove knockout A B or C This double knockout accommodates either 1 2 or 3 4 conduit Without Conduit Remo...

Страница 5: ...ceiling support grid is secured to the building structure 5 3 Remove one tile adjacent to the tile the enclosure will be mounted in 5 4 Secure four pieces of hanger wire not included to the building s...

Страница 6: ...b on the back of the cover 8 6 Snap the cover onto the base Note A second Cat5e Jack Module can be installed in position 2 of the surface mount box to provide access to the serial port on the WAP 6 1...

Страница 7: ...ion bracket Both pieces should be underneath the network cable and the ground cable 9 2 Place the remaining two pieces of fire resistant foam on top of the cables 9 3 Press down on the foam and slide...

Страница 8: ...upport www panduit com resources install_maintain asp www panduit com Page 8 of 8 PZWIFIED PZWIFIED with PZWIFIDCB Designed for Cisco Aironet 1232AP PZWIFIE PZWIFIE with PZWIFICB Designed for Cisco Ai...

Отзывы: