INSTRUCTIONS CM336
For instuctions in Local Languages
and Technical Support:
www.panduit.com/resources/install_maintain.asp
E-mail:
Fax:
(708)444-6448
www.panduit.com
To Wireless Antennas
Bulkhead
Cable
RS485
To RS485
connector
located
on patch
panel
Page 6 of 6
Step 6: Optional Fan Installation (if required, sold separately)
6.1 Break out vent space on bottom of enclosure.
6.2 Place fan over opening. Line up the bottom fan
cover to the outside of enclosure and screw
into place.
6.3 Line up top fan cover and screw into place.
6.4 Determine the length of the power cord that is
desired. Strip back the insulation on the cord
and terminate to the plug.
6.5 Attach the power cord. The fan can be plugged
into an Uninterruptable Power Supply (UPS) or
the electrical box inside the enclosure.
Break out
vent space
SYSTEM #1
SYSTEM #2
SYSTEM #3
SYSTEM #4
5.6
5.7
5.6 Wire individual control systems using panel duct as
cable management pathway.
Note: Follow NEC guidelines and/or local codes as
required.
5.7 Reattach perforated panel. Route and attach wireless antenna
bulkhead cables as shown.
5.8 Terminate device cables from perforated panel to corresponding patch panel connector or external system.
Note: For steps 5-8, make sure to employ appropriate grounding practices to ensure personal safety, as well as, to protect
sensitive electronic equipment.
5.9Energize system.
TERMINAL
BLOCK