INSTALLATION INSTRUCTIONS     PN155B

For Technical Support: www.panduit.com/resources/install_maintain.asp

Page 2 of 4

HEAT SHRINK TUBE

MULTIFIBER CABLE

1

41.4 in (105cm) Maximum

MULTIFIBER CABLE

2

3

0.5in (12.7mm)

BUFFERED FIBERS

4

COMBINED LENGTH OF BUFFER

AND FIBER REQUIRED FOR THE

CONNECTOR. (SEE CONNECTOR

INSTALLATION INSTRUCTIONS)

0.5in (12.7mm)

MARK ALL FURCATION TUBES

THAT WILL BE NEEDED

FURCATION TUBING

DRAW AN ‘X’ ON THIS SECTION

(THIS WILL BE CUT OFF)