TOOL OPERATION

(continued)

3.  Connect the coupling of the tool head onto the coupling of the hydraulic hose.

4.  Refer to the operation manual provided with your particular hydraulic pump system for the specific set-up operation,

and maintenance of the hydraulic pump.  Verify that the open areas between the ram and tool head are free of foreign
matter and debris that could jam or damage the tool during operation.  Cycle the tool head 2 or 3 times by activating
the hydraulic pump.  Be sure dies are in the tool head prior to cycling the tool. Check for leaks at all connections.

5.  Carefully place the connector between the dies so that the dies will crimp between the color bands on the connector.

Activate the pump to advance the ram until the connector is held by the dies.

CAUTION:

DO NOT crimp the connector at this time.

6.  Verify that the conductor size and dies properly match the connector size being used.  Insert the conductor complete-

ly into the connector barrel.

7.  Begin crimping by activating the hydraulic system.  The 

PANDUIT

CT-901HP and CT-8250HP Hydraulic Pumps incor-

porate a by-pass valve which, when activated, shuts off the pump when the crimp is completed.

8.  Deactivate the hydraulic system to retract the ram for removal or repositioning of the connector/conductor assembly.

MAINTENANCE

PERIODIC MAINTENANCE

1.  Daily maintenance is important to keep the tool in good working condition.  Keep the head clean and free of debris.

Excessive dirt and grit can contribute to the premature wear of the tool's mechanical parts.  Always replace the dust
cap on the connector fitting, and store the tool in its clean, dry carrying case when not in use.

2.  Particular attention should be made in keeping the tool head openings free of foreign matter and debris.  When using

the tool regularly, check that no foreign matter or debris exists in the open areas between the ram and tool head.
Thoroughly clean and lubricate the tool head.  A tool that is dirty with excessive foreign matter may jam and become
damaged during operation.

3.  The hydraulic system has been calibrated and sealed at the factory.  Consult our Tool Service Department if hydraulic

problems are experienced.

4.  As long as the daily maintenance procedures are adequately carried out, the tool will provide quality service for years.

However, if problems are experienced, please contact our Tool Service Department at (888) 506-5400, ext. 3255.

INSPECTION OF COMPRESSION FORCE

Inspect the compression force of the crimp head monthly, whenever possible damage has occurred, or as often as oper-
ating conditions warrant. 

CT-930CH, CT-930LPCH and CT-940CH OPERATING INSTRUCTIONS

Содержание CT-930CH

Страница 1: ...TEM SPECIFICATIONS 2 OPTIONAL ACCESSORIES 3 PRECAUTIONS AND GENERAL GUIDELINES FOR MAINTENANCE OF TOOLS 4 DIE SELECTION 4 Die Identification 5 DIE INSTALLATION 5 TOOL OPERATION 6 MAINTENANCE Periodic...

Страница 2: ...to 15 0 tons 13 6 metric tons of compressive force This manual will guide you step by step in the operation and maintenance of your Remote Hydraulic Crimping Tool If you have problems not covered cal...

Страница 3: ...8 kg Hydraulic Fittings Parker Hannifin 3 8 Female Quick Coupler Carrying Case Included with CT 940CH Tool Compression Dies CT 930CH CT 930LPCH Refer to PANDUIT catalog or Sales Office for part number...

Страница 4: ...excessive foreign matter may jam and become damaged during operation 7 To ensure a quality connection the CT 930CH and CT 940CH Tools must be used with a hydraulic pump capable of developing and sust...

Страница 5: ...ANDUIT PART NUMBER DIE COLOR DOT DIE COLOR CODE AND DIE INDEX NUMBER FOR COPPER AND ALUMINUM COMPRESSION DIES CAUTION DO NOT operate tool without dies installed 1 Select the appropriate dies to match...

Страница 6: ...ings are matched to the tool head fittings The CT 930LPCH Tool Head must be operated with a compatible hydraulic pump system capable of developing and sustaining 7 500 PSI 525 kg cm2 PANDUIT s CT 8250...

Страница 7: ...retract the ram for removal or repositioning of the connector conductor assembly MAINTENANCE PERIODIC MAINTENANCE 1 Daily maintenance is important to keep the tool in good working condition Keep the...

Отзывы: