4.4.4
Batteries
The HFP36v works with two 18v batteries in series. It is necessary to have 2 batteries to make it work.
Before use, check the charge level of the batteries by pressing the test button. If a battery shows only one light,
remove it and use a different one.
The HFP checks the battery voltage before starting each cycle. If the voltage is too low to complete a cycle, the HFP
will not start and illuminate the low battery indicator. (see 4.4.6 Control panel)
To preserve the longevity of the batteries, it is advisable to avoid using a full battery with an empty battery.
Charging a battery takes about an hour. The autonomy of the HFP with 2 full batteries is 8 preheating cycles of 8
minutes.
Checking the charge level