72 av 82
OPERATION AND MAINTENANCE MANUAL I ENG_OMM_CD200IQ_P03 I 2023-03-16
@Pandrol 2023
Fig 108. Drain plug
1.
Drain the hydraulic system via the drain plug at the bottom of hydraulic fluid tank.
IMPORTANT!
Empty the contaminated fluid in a approved container with capacity according to the
hydraulic system volume.
2.
Replace the hydraulic filters.
3.
Fill the hydraulic fluid tank according to specification below. The system volume is
approximately 7 L. Use the dipstick to check the fluid level.
11.8.
Changing hydrailic fluid
Hydraulic fluid specification
Fluid used for filling must be clean. No not mix different typer
of hydraulic fluid. Hydraulic fluid approved by Pandrol must
fulfill one of the standards given below.
• DIN 51524 del 3
• SS 15 54 34
• ISO 11158 HV
Example: Shell Tellus S2 M46, BP Bartran HV 46.
Hydraulic fluid suppliers must be able to verify that the quality
and prestanda fulfill the standards given above. Always
contact Pandrol if the hydraulic fluid will be replaced with a
non-mineral fluid such as syntetic or biograde fluid.
Panolin HLP SYNTH 46.
Fluid viscosity
The fluid viscocity is of grat importance to
achieve the best possible efficiency within
the hydraulic system. The numbering of fluid
in the table below showing the viscosity at
40°C.
Fluid viscosity at 40° C
Temperatur
32
-25°C to 75°C
46
-15°C to 90°C
68
-5°C to 90°C
If the machine is used in an arctic
environment, a fluid with viscosity lower
than 32 shall be used.
Содержание CD200 IQ
Страница 1: ...Partners in excellence ENG_OMM_CD200IQ_P03 2023 03 16 CD200 IQ OPERATION AND MAINTENANCE MANUAL...
Страница 2: ...2 av 82 OPERATION AND MAINTENANCE MANUAL I ENG_OMM_CD200IQ_P03 I 2023 03 16 Pandrol 2023...
Страница 53: ...53 av 82 OPERATION AND MAINTENANCE MANUAL I ENG_OMM_CD200IQ_P03 I 2023 03 16 Pandrol 2023...
Страница 80: ...80 av 82 OPERATION AND MAINTENANCE MANUAL I ENG_OMM_CD200IQ_P03 I 2023 03 16 Pandrol 2023...
Страница 81: ...81 av 82 OPERATION AND MAINTENANCE MANUAL I ENG_OMM_CD200IQ_P03 I 2023 03 16 Pandrol 2023...