- 2 -
ZVP-PC-0100-00-R1
4.0
OPERATING INSTRUCTIONS
! WARNING! – READ THIS SECTION
CAREFULLY BEFORE USING THIS EQUIPMENT
APPARATUS.
4.1
Ensure that the 19mm (3/4
″
) air inlet ball
valve located on the Top Lid is in the isolated
closed position.
4.2
Slowly turn on your compressed air supply
source.
4.3
To commence the abrasive recovery process,
slowly turn the 19mm (3/4
″
) air inlet ball valve
on the Top Lid cover to the open position.
4.4
Position the tapered end of the abrasive pick up
wand as close as possible to the abrasive and
commence the abrasive recovery process.
NOTE: NEVER ISOLATE, CLOSE OR BLOCK THE
AIR BREATHER HOLE LOCATED ON THE
ABRASIVE PICK UP WAND. ISOLATING THE
AIR BREATHER HOLE WILL IMPAIR THE
VACUUM FUNCTION.
4.5
To stop the abrasive recovery operation, close
the 19mm (3/4
″
) air inlet ball valve located on
the Top Lid cover.
! WARNING! – IT IS RECOMMENDED THAT
APPROVED HEARING PREOTECTION IS WORN
DURING THE OPERATION OF THIS
EQUIPMENT/APPARATUS.
5.0
MAINTENANCE
! WARNING! – THE COMPRESSED AIR
SOURCE MUST BE ISOLATED BEFORE
PERFORMING ANY MAINTENANCE WORK.
FAILING TO DO SO MAY CAUSE SERIOUS
INJURY OR DEATH.
5.1
Periodically remove the Dust Bag from the Top
Lid and blow down with dry compressed air.
The Dust Bag may also be washed in water with
a mild detergent and air dried. Replace the dust
bag if any holes or if any excessive reduction of
the vacuum suction is detected.
5.2
Check the abrasive Recovery Hose after each
operation for any signs of cracks, holes or wear.
It is recommended that the abrasive Recovery
Hose be kept as straight as possible and
horizontal during the vacuum recovery
operation. Avoid sharp radius bending of the
abrasive Recovery Hose during operation to
extend the service life of the abrasive Recovery
Hose.
5.3
Inspect the abrasive pick up wand and remove
any debris that may be caught in the abrasive
pick up wand section prior to each operation.
! WARNING! – NEVER ATTEMPT TO PICK UP
OR MOVE THE DRUM DURING OR AFTER
OPERATION AS IT MAY CAUSE SERIOUS
INJURY. OPTIONAL BAC-RV-PB-0018 (DRUM
CLAMPING KIT) IS AVAILABLE FOR EASE OF
DRUM RELOCATION.
6.0
TROUBLE SHOOTING
PROBLEM PROBABLE
SOLUTION
System not
recovering the
abrasive media
Check if the incoming compressed air
supply meets the minimum air supply
requirement.
Check the breather hole on the
abrasive pick up wand is not
obstructed.
Check the dust bag and ensure that it
is not blocked with fine dust. Clean or
replace the dust bag.
Check the recovery hose for any wear.
Replace if necessary.
Check the pick up wand and remove
any oversize debris that may have
been caught during operation.