12
5.2
Front panel
○
1
○
2
○
3
○
4
○
5
○
6
○
7
○
8
○
9
○
10
○
11
○
12
○
13
○
14
○
15
○
16
○
17
○
19
○
18
NO.
name
description
○
1
temperature
abnomal indicator
● When abnormal rise in important components temperature occurs,
temperature abnomal alarm is sent, this lamp blinks and the welding
operation stops. Welding operation cannot be restarted unless this lamp is
turned off. ( For troubleshooting:
Section 13.1).
○
2
current display
7-segment LED
When Mode selection key
○
12
is set to“ Weld ”
・
On stand-by status,, it shows the current value set in
○
3
・
During welding, it shows the current value of the actual output.
● When Mode selection key
○
12
is set to“F. Adj” (
Section 5.4)
・
It shows fine adjusting setting items PXX(XX stands for 00->29), default
display CH-OFF( voltage display LED
○
5
shows its specific set value ).
● When Mode selection key
○
12
is set to “ Call ” (
Section 5.6)
・
The default display CH-OFF. By turning the Jog-dial
○
7
, select channel
number, LED shows “CH” channel. If welding parameters are available,
the channel can be selected, else the corresponding channel can NOT be
selected. When the channel stored with data is selected, the channel and
parameters are displayed alternately and welding can start.
● When Mode selection key
○
12
is set to “ Record ” (
Section 5.6)
・
By turning the Jog-dial
○
7
, channel number can be selected. LED shows
“CH” setting current and voltage. Flashing means welding parameters are
being stored.
・
Press selection key
○
12
to return to “ Weld ” from “ Record ” and the
corresponding parameters are recorded in the channel being selected.
● When a self-diagnosable error occurs, ( For troubleshooting:
Section 13.1)
・
it shows Err( voltage display LED
○
3
shows alarm signal number ).
○
3
setting
“ current ”
“ wire feeding
speed ”
“ plate thickness ”
“ spot welding
time ”
function select
● When “ current ” / “ wire feeding speed ” function is selected, the
setting method of the corrosponding selection number is decided by P11
of “F. Adj” function menu. When P11 is 0, it is adjusted by wire feeder
potentiometer; when P11 is 1, it can be changed by Jog-dial ○
4. Note
“ plate thickness ” can be displayed only instead of being changed.
●“ spot welding time ” function is adjusted by Jog-dial ○
4.
Note To change“ spot welding time ”, welding control ○
13 is to be
selected as “ spot welding ” function.
Names and functions
Содержание YD-350GL4
Страница 45: ...41 1 2 3 4 5 6 7 8 9 10 11 12 13 14 14 40 41 43 44 45 Right view Left view Parts list ...
Страница 49: ...45 1 2 3 4 5 6 7 8 9 10 11 12 13 14 14 40 41 43 44 45 Right view Left view Parts list ...
Страница 52: ...Circuit diagram 48 13 Circuit diagram 13 1 Circuit diagram for 350GL4 100V 100V Optional parts 300 246 ...
Страница 53: ...Circuit diagram 49 13 1 Circuit diagram for 500GL4 100V 100V Optional parts 300 248 ...