28
11 Specifications
Modelnumber
YC-400TX4HGH
YC-400TX4HJE
Rated input voltage
V
380
415
Number of phases
-
3
3
Rated input voltage
V
380±10%
415±10%
Rated frequency
Hz
50/60
50/60
Rated input
T I G
kVA
13.5
14.5
Stick
17.85
21.4
Rated Output
T I G
kW
12.8
12.4
Stick
17
17
Power Factor
0.95
0.95
Rated No-Load Voltage
V
73
73
Output current
adjustable range
T I G
A
4
~
400
4
~
400
STICK
A
4
~
400
4
~
400
Output voltage
adjustable range
*
T I G
V
10.2
~
26
10.2
~
26
STICK
V
20.2
~
36
20.2
~
36
Initial current
A
4
~
400
4
~
400
Pulse current
A
4
~
400
4
~
400
Crater current
A
4
~
400
4
~
400
Rated Duty Cycle
%
60
60
Control method
IGBT Inverter type
IGBT Inverter type
Cooling method
Forced air-cooling
Forced air-cooling
High-frequency generator
Spark-oscillation type
Spark-oscillation type
Pre-flow time
s
0
~
30
0
~
30
Post-flow time
s
0
~
30
0
~
30
Up-slope time
s
0
~
20
0
~
20
Down-slope time
s
0
~
20
0
~
20
Arc spot time
s
0.1
~
30
0.1
~
30
Pulse frequency
Hz
0.1
~
500
0.1
~
500
Pulse width
%
5
~
95
5
~
95
Crater control process
Three
mode(ON,OFF,REPEAT)
Three
mode(ON,OFF,REPEAT)
Dimensions
(W×D×H)
mm
340×600×610
340×600×610
Mass
kg
44
44
Insulation class
130
℃
(
reactor 180
℃
)
130
℃
(
reactor 180
℃
)
EMC
classification
A
A
IP code
IP23
IP23
Содержание YC-400TX4
Страница 2: ......
Страница 17: ...11 5 2TIG PLUSE TIG WATER ...
Страница 35: ...29 12 Parts list 12 1 Parts list for YC 400TX4 Front view 1 3 4 5 2 6 ...
Страница 36: ...30 Right View Left view 7 12 11 13 19 20 10 8 9 21 14 15 18 16 17 23 22 26 24 27 25 ...
Страница 38: ...32 13 Outline drawing ...
Страница 39: ...33 14 Circuit diagram ...