51
SW
1
AC24VONL
Y
RS485Setting
S TA RT
REAR
SW
2
8-bit DIP
SW
O
N
1
2
3
4
5
6
7
8
4-bit DIP
SW
ON
1
2
3
4
Camera top view
Seal
Switch view
SW1
SW2
1
2
3
4
ON
5
6
7
8
Switch position
Returns to the factory default settings.
1
2
3
4
ON
5
6
7
8
Switch position
Multiplex-Coaxial communication
1
2
3
4
ON
5
6
7
8
1
2
3
4
ON
5
6
7
8
1
2
3
4
ON
5
6
7
8
Switch position
Baud rate
1
1
1
None
None
None
8
8
8
19 200
9 600
4 800
Data bit
Parity
check
Stop
bit
Parameter selection
4. Setting the Switches
The 8-bit DIP switch has two functions. It is
used to restore the factory default settings
and to specify the unit number. Before set-
ting, peel off the seal covering the switch
holes. After setting the switch, replace the
seal. The 4-bit DIP switch selects termina-
tion ON/OFF and half/full duplex for RS485
communication. The switch settings are
read into the camera when the power is
turned on. After changing the switch set-
tings, be sure to turn the power off, then turn
it back on again. Switch positions and func-
tions are shown below.
RS485 Parameter Setup
The selected protocol, communication para-
meters, and set unit numbers are read into
the camera when the power is switched on.
(1) Switch off the camera.
(2) Set the switch as shown in the table
below.
(3) Set the unit number with the DIP switch
(see the next page).
(4) Switch on the camera to read in the
changed switch settings.
Note:
The changed communication
parameters are displayed on the
RS485 SETUP menu after the cam-