48
Unit Number (UNIT NUMBER)
Displays the unit number set by the DIP switch. If the switch is set to
1-96, select a number by moving the joystick to the right or left. In an
RS485 chain each unit must have a unique number.
Factory default setting: 1. See INSTALLATION for DIP switch setting.
Sub Address (SUB ADDRESS)
Do not set.
Baud Rate (BAUD RATE)
Specifies the transmission speed (2 400, 4 800, 9 600, 19 200 bit per second) for the RS485 communica-
tion. The factory default setting is 19 200.
Data Bit (DATA BIT)
Specifies the number of data bits (7 or 8 bits) for the RS485 communication. The factory default setting is
8.
Parity Check (PARITY CHECK)
Specifies the parity check mode (NONE, ODD, EVEN). The factory default setting is NONE.
Stop Bit (STOP BIT)
Specifies the number of stop bits (1 or 2 bits). The factory default setting is 1.
X ON/X OFF (X ON/X OFF)
Specifies whether to apply flow control or not (USE or NOT USE). The factory default setting is NOT USE.
Wait Time (WAIT TIME)
Specifies the time to wait until retrying after confirming that no data is received from the controller.
(OFF: no retry, 100, 200, 400, 1 000 ms).
The factory default setting is OFF.
Alarm Data (ALARM DATA)
Specifies the alarm transmission mode depending on the protocol selected by the 8-bit DIP switch.
POLLING:
Transmits the alarm data in response to requests from the controller.
AUTO 1:
Transmits the alarm data each time an alarm signal is received by the camera.
AUTO 2 (Default):
Transmits alarm data at intervals of 5 seconds.
Delay Time (DELAY TIME)
Specifies the time to transmit the acknowledge request when communicating on a 2-line connection.
[----, 100 ms] Factory default setting: ---- (no set).
This menu appears only when a 2-line communication is used. Make sure to be 100 ms when connecting
the camera with the WJ-FS616 Video Multiplexer or Matrix Switcher WJ-SX350 in a 2-line communication
system.
The settings become effective with the closing of SET UP MENU.
Note:
Set the same parameters for the cameras, controllers and personal computers in an RS485 chain.
** RS485 SET UP **
UNIT NUMBER
SUB ADDRESS
BAUD RATE
DATA BIT
PARITY CHECK
STOP BIT
XON/XOFF
WAIT TIME
ALARM DATA
DELAY TIME
RET
1
-----
19200
8
NONE
1
NOT USE
OFF
AUTO2
---
RS485 Setup menu