34
Step 5
Adjust the oscilloscope to the horizontal rate, and extend the horizontal synchronizing part of
the oscilloscope.
Move the cursor horizontally to adjust the horizontal phase with use of the right or left button.
Adjustable range: 0 to –2.0 µs
Adjustment of phase in power supply synchronization mode (LL)
The adjusting video signal of the camera and the criterial external synchronizing input signal
are connected to a 2-input oscilloscope and the phase is adjusted.
Note:
Movement of the camera or presence of a spike noise in the AC line may cause vertical
phase change. In such a case, adjust the phase again.
Follow the procedure in the next page to adjust the phase.
**SYNC**
V PHASE
COARSE 1(1--16)
FINE ...|...128
- +
RET TOP END
**CAMERA SETUP** 1/2
CAMERA ID OFF
ALC/ELC ALC
SHUTTER OFF
AGC ON
SENS UP OFF
SYNC INT
WHITE BAL ATW1
MOTION DET OFF
DNR HIGH
RESOLUTION HIGH
BW MODE
"CAMERA SETUP" screen
"SYNC" screen
Step 2
Connect the video output signal and external
synchronizing input signal of the camera to a
2-input oscilloscope, and move the cursor to
"COARSE".
Step 3
Adjust the oscilloscope to the vertical rate,
and extend the vertical synchronizing part of
the oscilloscope.
Move the cursor horizontally to adjust the ver-
tical phase with use of the right or left button.
The phase can be adjusted in 16 steps by
22.5 degrees.
1 (1--16) : 0 °/2 (1--16) : 22.5 °/ ...../16 (1--16)
: 337.5 °
Step 4
Move the cursor to "FINE", and move the cur-
sor horizontally with use of the right or left
button to adjust both vertical phases.
Step 1
Set "SYNC" to "LL" and press the setting but-
ton.
→
The "SYNC" screen appears.