4.
To invalidate the VMD area, click the [Set] button after selecting “Off” for “Status” of the VMD area to be
invalidated.
→
The outline of the invalidated VMD area will turn to a dotted line. When the VMD area is invalidated,
no alarm will occur even when a motion can be recognized in the area.
5.
To delete the VMD area, click the [Delete] button corresponding to the area to be deleted.
→
The outline of the respective VMD area will disappear.
6.
Click the [Set] button.
→
The edited settings will be applied.
7.
Click the [Back] button to return to the screen to select a preset position.
13.8 Configuration of the settings relating to the mail
notification [Notification]
Click the [Notification] tab on the “Alarm” page. (
®
page 47, page 49)
The settings relating to the alarm mail can be configured. It is necessary to configure the settings of the mail
server to perform the mail notification. (
®
page 161)
Mail notification
[Mail server >>]
When “Mail server >>” is clicked, the [Mail] tab of the “Server” page will be displayed. (
®
page 161)
[Mail notification]
Select “On” or “Off” to determine whether or not to provide notification by e-mail according to the settings for
the “Alarm” and “Diag.” checkboxes of “Destination of notification” below.
–
When an alarm is detected (“Alarm”)
SW396
SW396
SW395
SW395
SC386
SC386
SC385
SC385
SC384
SC384
SW175
SW175
SW172
SW172
ST165
ST165
ST162
ST162
:
Operating Instructions
147
13 Configure the alarm settings [Alarm]