1-64
SW395
SW395
SC385
SC385
SC384
SC384
SW175
SW175
SW174W
SW174W
SW172
SW172
ST165
ST165
ST162
ST162
:
When the registered
preset position is selected, the camera will move to the selected preset position when a terminal alarm 2
is detected.
•
Auto track
SW395
SW395
SC385
SC385
:
When a terminal alarm 2 is detected, the camera will start the auto tracking.
•
1-256
SW396
SW396
SC386
SC386
:
If a previously registered preset position is selected, when a terminal alarm 2 is
detected, the camera will move to that position.
•
Auto track
SW396
SW396
SC386
SC386
:
When a terminal alarm 2 is detected, the camera will start the auto tracking.
•
Patrol 2
SW396
SW396
SC386
SC386
:
When a terminal alarm 2 is detected, the camera will start the patrol.
* If Patrol 2 is not registered it is not displayed on the screen.
•
Default:
Off
[Terminal alarm 3]
Select an action to be taken when a terminal alarm 3 is detected from the following.
•
Off:
Does not take any action even when a terminal alarm 3 is detected.
•
1-64
SW395
SW395
SC385
SC385
SC384
SC384
SW175
SW175
SW174W
SW174W
SW172
SW172
ST165
ST165
ST162
ST162
:
When the registered
preset position is selected, the camera will move to the selected preset position when a terminal alarm 3
is detected.
•
Auto track
SW395
SW395
SC385
SC385
:
When a terminal alarm 3 is detected, the camera will start the auto tracking.
•
1-256
SW396
SW396
SC386
SC386
:
If a previously registered preset position is selected, when a terminal alarm 3 is
detected, the camera will move to that position.
•
Auto track
SW396
SW396
SC386
SC386
:
When a terminal alarm 3 is detected, the camera will start the auto tracking.
•
Patrol 3
SW396
SW396
SC386
SC386
:
When a terminal alarm 3 is detected, the camera will start the patrol.
* If Patrol 3 is not registered it is not displayed on the screen.
•
Default:
Off
[VMD alarm]
Select an action to be taken when a VMD alarm is detected from the following.
•
Off:
Does not take any action even when a VMD alarm is detected.
•
1-64
SW395
SW395
SC385
SC385
SC384
SC384
SW175
SW175
SW174W
SW174W
SW172
SW172
ST165
ST165
ST162
ST162
:
When the registered
preset position is selected, the camera will move to the selected preset position when a VMD alarm is
detected.
•
Auto track
SW395
SW395
SC385
SC385
:
When a VMD alarm is detected, the camera will start the auto tracking.
•
1-256
SW396
SW396
SC386
SC386
:
If a previously registered preset position is selected, when a terminal alarm 1 is
detected, the camera will move to that position.
•
Auto track
SW396
SW396
SC386
SC386
:
When a VMD alarm is detected, the camera will start the auto tracking.
•
Patrol 1
SW396
SW396
SC386
SC386
:
When a VMD alarm is detected, the camera will start the patrol.
* If Patrol 1 is not registered it is not displayed on the screen.
•
Default:
Off
[Command alarm]
Select an action to be taken when a command alarm is detected from the following.
•
Off:
Does not take any action even when a command alarm is detected.
•
1-64
SW395
SW395
SC385
SC385
SC384
SC384
SW175
SW175
SW174W
SW174W
SW172
SW172
ST165
ST165
ST162
ST162
:
When the registered
preset position is selected, the camera will move to the selected preset position when a command alarm
is detected.
•
Auto track
SW395
SW395
SC385
SC385
:
When a command alarm is detected, the camera will start the auto tracking.
•
1-256
SW396
SW396
SC386
SC386
:
If a previously registered preset position is selected, when a terminal alarm 1 is
detected, the camera will move to that position.
•
Auto track
SW396
SW396
SC386
SC386
:
When a command alarm is detected, the camera will start the auto tracking.
•
Patrol 1
SW396
SW396
SC386
SC386
:
When a command alarm is detected, the camera will start the patrol.
* If Patrol 1 is not registered it is not displayed on the screen.
Operating Instructions
137
13 Configure the alarm settings [Alarm]