-28-
5. Move the cursor to H PHASE. The cursor starts
blinking.
6. Supply the video output signal of the camera to be
adjusted and the reference gen-lock input signal
to a dual-trace oscilloscope.
7. Set the oscilloscope to the horizontal rate and
expand the horizontal sync portion on the oscillo-
scope.
8. Adjust the horizontal phase by pressing
or
. The adjustable range is 0 - 2.0µs.
5-3. Line-lock Sync Mode (LL)
Note:
The line-lock (LL) sync mode is not available
when the camera operates on DC power.
1. Move the cursor to the SYNC parameter and
select LL.
Note:
The settings in this menu can be made only
when the multiplexed vertical drive signal
(VD2) is not supplied to the camera.
** SYNC **
H PHASE ........I
- +
RET END
2. After confirming the cursor is on LL, press
.
The vertical phase adjustment menu appears on
the monitor.
3. Move the cursor to COARSE. The cursor starts
blinking.
4. Supply the video output signal of the camera to be
adjusted and the reference camera video output
signal to a dual-trace oscilloscope.
5. Set the oscilloscope to the vertical rate and
expand the vertical sync portion on the oscillo-
scope.
6. Press
or
to match the vertical phase for
both video output signals as closely as possible.
(COARSE adjustment can be incremented in 16
steps by 22.5 degrees by pressing
or
.)
** SYNC **
V PHASE
COARSE 1(1--16)
FINE I........
- +
RET END
Содержание WV-CP450
Страница 3: ......