2-3
8
Referring to Fig. 2-7, remove two screws that secure the
CCD Bottom Case and remove the CCD Bottom Case
from the Camera Unit.
8
Referring to Fig. 2-8, disconnect the connectors between
CN2 on the Sensor Board and CN1 on the Main Board,
remove the Main Board from the Camera Unit.
8
Referring to Fig. 2-9, remove two screws that secure the
Sensor Board and remove the Sensor Board from the
Camera Unit.
Fig. 2-7
8
Confirm that removed the Sensor Board and the Main
Board from the Camera Unit as shown in Fig. 2-10.
8
Referring to Fig. 2-11, reconnect the connectors by using
the Extension Cable (Refer to Fig. 1-3) and the Extension
Board Ass'y (Refer to Fig. 1-4) between CN2 on the
Sensor Board and CN1 on the Main Board for Servicing.
Fig. 2-8
Camera Unit
CN2
Sensor Board
CN1
Main Board
Fig. 2-9
Remove two screws.
Camera Unit
Sensor Board
Fig. 2-11
Main Board
Extension
Board Ass'y
Sensor Board
Extension Cable
Fig. 2-10
Sensor Board
Main Board
Remove two screws.
CCD Bottom Case
Camera Unit