manualshive.com logo in svg
background image

The lightning flash with arrowhead
symbol, within an equilateral triangle, is
interned to alert the user to the
presence of uninsulated "dangerous
voltage" within the product's enclosure
that may be of sufficient magnitude to
constitute a risk of electric shock to
persons.

The exclamation point within an
equilateral triangle is intended to alert
the user to the presence of important
operating and maintenance (servicing)
instructions in the literature
accompanying the appliance.

The serial number of this product may be found on the
bottom of the unit.
You should note the serial number of this unit in the
space provided and retain this book as a permanent
record of your purchase to aid identification in the event
of theft.

Model No.

Serial No.

CAUTION:
TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK), NO
USER SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE
PERSONNEL.

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

ENGLISH VERSION

THIS APPARATUS MUST BE EARTHED.

To ensure safe operation the three-pin plug supplied must be
inserted only into a standard three-pin power point which is
effectively earthed through the normal household wiring.
Extension cords used with the equipment must be three-core and
be correctly wired to provide connection to earth. Wrongly wired
extension cords are a major cause of fatalities.
The fact that the equipment operates satisfactorily does not imply
that the power point is earthed and that the installation is
completely safe. For your safety, if in any doubt about the
effective earthing of the power point, consult a qualified
electrician.

For Australia

For U.K.

FOR YOUR SAFETY PLEASE READ THE FOLLOWING TEXT
CAREFULLY.
This appliance is supplied with a moulded three pin mains plug for your
safety and convenience.
A 13 amp fuse is fitted in this plug.
Should the fuse need to be replaced please ensure that the replacement
fuse has a rating of 13 amp and that it is approved by ASTA or BSI to
BS1362.
Check for the ASTA mark 

H

or the BSI mark 

G

on the body of the

fuse.
If the plug contains a removable fuse cover you must ensure that it is
refitted when the fuse is replaced.
If you lose the fuse cover the plug must not be used until a replacement
cover is obtained.
A replacement fuse cover can be purchased from your local Panasonic
Dealer.

IF THE FITTED MOULDED PLUG IS UNSUITABLE FOR THE
SOCKET OUTLET IN YOUR HOME THEN THE FUSE SHOULD BE
REMOVED AND THE PLUG CUT OFF AND DISPOSED OF SAFELY.
THERE IS A DANGER OF SEVERE ELECTRICAL SHOCK IF THE
CUT OFF PLUG IS INSERTED INTO ANY 13 AMP SOCKET.
If a new plug is to be fitted please observe the wiring code as shown
below.
If in any doubt please consult a qualified electrician.
WARNING:

This apparatus must be earthed.

IMPORTANT

The wires in this mains lead are coloured in accordance with the
following code.

Green-and-yellow:

Earth

Blue:

Neutral

Brown:

Live

As the colours of the wire in the mains lead of this appliance may

not correspond with the coloured markings identifying the terminals in
your plug, proceed as follows.

The wire which is coloured green-and-yellow must be connected to

the terminal in the plug which is marked with the letter E or by the earth
symbol 

I

or coloured green or green-and-yellow.

The wire which is coloured blue must be connected to the terminal

in the plug which is marked with the letter or coloured black.

The wire which is coloured brown must be connected to the

terminal in the plug which is marked
with the letter or coloured red.

How to replace the fuse
Open the fuse compartment with
a screwdriver and replace the fuse
and fuse cover.

WARNING:  TO PREVENT FIRE OR ELECTRIC SHOCK HAZARD, DO NOT EXPOSE THIS APPLIANCE TO

RAIN OR MOISTURE.

Wij verklaren als enige aansprakelijke, dat het product
waarop deze verklaring betrekking heeft, voldoet aan de
volgende normen of andere normatiefve dokumenten,
overeenkomstig de bepalingen van Richtlijnen 73/23/EEC en
89/336/EEC.

Vi erklærer os eneansvarlige for, at dette produkt, som denne
deklaration omhandler, er i overensstemmelse med den
følgende standarder eller andre normative dokumenter i følge
bestemmelserne i direktivene 73/23/EEC og 89/336/EEC.

Vi deklarerar härmed värt fulla ansvar för att den produkt till
vilken denna deklaration hänvisar är i överensstämmelse
med standarddokument, eller andra normativa dokument som
framstölls i Direktiv 73/23/EEC och 89/336/EEC.

Ilmoitamme yksinomaisella vastuullamme, että tuote, jota
tämä ilmoitus koskee, noudattaa seuraavia standardeja tai
muita ohjeellisia asiakirjoja, jotka noudattavat direktiivien
73/23/EEC ia 89/336/EEC. säädöksiä.

Vi erklærer oss alene ansvarlige for at produktet som denne
erklæringen gjelder for, er i overensstemmelse med følgende
normer eller andre normgivende dokumenter som fælger
bestemmelsene i direktiven 73/23/EEC og 89/336/EEC.

We declare under our sole responsibility that the product
to which this declaration relates is in conformity with the
standards or other normative documents following the
provisions of Directives EEC/73/23 and EEC/89/336.

Noi dichiariamo sotto nostra esclusiva responsabilità che il
prodotto a cui si riferisce la presente dichiarazione risulta
conforme ai seguenti standard o altri documenti normativi
conformi alle disposizioni delle direttive CEE/73/23 e
CEE/89/336.

Содержание WV-BS300

Страница 1: ...Combination Camera WV BS300 Before attempting to connect or operate this product please read these instructions completely...

Страница 2: ...D INTO ANY 13 AMP SOCKET If a new plug is to be fitted please observe the wiring code as shown below If in any doubt please consult a qualified electrician WARNING This apparatus must be earthed IMPOR...

Страница 3: ......

Страница 4: ...E 4 Setup Menu 4 Setup Menu Description 6 Setting Procedures 8 INSTALLATION 17 CONNECTIONS 19 SYSTEM CONNECTION 20 PREVENTION OF BLOOMING AND SMEAR 21 SPECIFICATIONS 22 ACCESSORIES 22 OPTIONAL ACCESSO...

Страница 5: ...picture sharpness b Minimum of aliasing on fine objects c Expanded dynamic range by use of knee circuit d Highlight aperture correction for greater picture detail of bright object 8 Back Light Compen...

Страница 6: ...MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS 1 Video Output Connector 2 Power Cable 3 Camera Mounting Angle 4 Pan Tilt Starting Point 5 Fall Prevention Wire 6 Decoration Cover 7 Dome Cover q w e r t y...

Страница 7: ...the cursor upward downward right left and select the mode Also used to adjust the level CAM SET Button The mode is set by this button Also the menus can be changed by this button SETUP PROCEDURE Setu...

Страница 8: ...t The mode is also selected by this switch and adjustment of certain levels can be made by this switch Left Switch Moves the cursor to the left The mode is also selected by this switch and adjustment...

Страница 9: ...ion function to overcome this problem Setup menu tree both the ALC light control modes can select either preset ON or OFF for back light compensation WV BS300 Preset ON B Conventional Camera Night Day...

Страница 10: ...lens iris when in the ALC mode or a exposure time control signal to the CCD image sensor when in the ELC mode 3 Shutter Speed SHUTTER The electronic shutter speed can be selected from 1 50 second OFF...

Страница 11: ...nning manually AUTO PAN Operates the panning automatically with the preset panning range SET UP CAMERA ID OFF ALC MANUAL ALC SHUTTER OFF AGC ON SYNC INT AUTO PAN OFF SPECIAL MENU DISPLAY Setup Menu Di...

Страница 12: ...ter is written to the editing cursor position The blinking editing cursor moves to the right automatically at this moment Repeat the above procedure until all character editing is completed When the p...

Страница 13: ...tup menu If necessary refer to Setup Menu Display on page 8 for details on displaying the setup menu on the monitor screen Move the cursor to ALC MANUAL and select either ALC or MANUAL by using the jo...

Страница 14: ...ess the CAM SET button to mask that area The area turns to white When the cursor is moved to an area that has already been masked the mask and cursor start blinking alternately Press the CAM SET butto...

Страница 15: ...etup Menu Display on page 8 for details on displaying the setup menu on the monitor screen Move the cursor to SHUTTER and select the electronic shutter speed by using the joystick The following electr...

Страница 16: ...e Camera 1 to the dual trace oscilloscope Set the dual trace oscilloscope to the vertical rate and expand the vertical sync portion on the oscilloscope Control the joystick to match as closely as poss...

Страница 17: ...AUTO PAN and select either ON or OFF by moving the joystick to the left or right SET UP CAMERA ID OFF ALC MANUAL ALC SHUTTER OFF AGC ON SYNC INT AUTO PAN OFF SPECIAL Setup menu 2 When AUTO PAN is sel...

Страница 18: ...I L H ENDLESS ON STOP TIME 2S RET 8 Special Menu This menu lets the customer adjust and setup the video signal of the camera to meet the customer s requirement Display the setup menu If necessary ref...

Страница 19: ...menu Move the cursor to RET by using the joystick and press the joystick The setup menu is displayed How to reset to factory setup Any of the above settings plus the ALC MANUAL level control and phas...

Страница 20: ...the following Note Be sure to protect the video and power cables Otherwise these cables will be damaged with the cutting surface b The cables go through into the ceiling 1 Remove the mounting screw M...

Страница 21: ...unt ing angle a In case of coming the cables from the side Pass the cables into the pre made hole refer to a The cables come from the side in INSTALLATION on the decoration cover b In case of going th...

Страница 22: ...he self check operation the zooming and focusing are operated once is done after turning on the power When the AUTO PAN ON mode has been selected panning will start automatically Coaxial cable length...

Страница 23: ...8 CAMERA IN VIDEO OUT1 VIDEO OUT2 INPUT 1 2 3 4 5 6 7 8 CAMERA IN VIDEO OUT1 VIDEO OUT2 INPUT 1 2 3 4 5 6 7 8 CAMERA IN VIDEO OUT1 VIDEO OUT2 INPUT 1 2 3 4 5 6 7 8 CAMERA IN VIDEO OUT1 VIDEO OUT2 INP...

Страница 24: ...aimed at a bright light such as a spot light or a surface that reflects bright light smear or blooming may appear Therefore the camera should be operated carefully in the vicinity of extremely bright...

Страница 25: ...nual Iris Auto Open Close is possible MANUAL Maximum Aperture Ratio 1 1 2 WIDE 1 9 TELE Focal Length 5 50 mm Electronic Shutter 1 50 OFF 1 120 1 250 1 500 1 1000 1 2000 1 4000 1 10000 Back Light Compe...

Отзывы: