<Emitter>
Emits light toward the facing receiver. The status of the emitter is indicated by the indicators.
<Receiver>
Receives light from the facing emitter. The control output (OSSD 1 / 2) turns ON when light from
the emitter is received on all beam channels, and turns OFF when light is blocked on one or
more beam channels. [Except when the muting function or blanking function (Note) is used.]
The status of the receiver is indicated by the indicators.
Note: Blanking function settings are configured using the communication module
SF4D-TM1
(option) and Con-
figurator Light Curtain software.
Please purchase the
SF4D-TM1
communication module separately. The Configurator Light Curtain soft
-
ware can be downloaded free-of-charge from our website (
panasonic.net/id/pidsx/global
).
<Beam channels>
Light emitting elements are arranged in the emitter and light receiving elements are arranged in
the receiver at intervals of 10mm (
SF4D-F□
), 20mm (
SF4D-H□
), or 40mm (
SF4D-A□
).
<Indicators>
Emitter:
Light emission intensity control indicator
Receiver:
Function setting indicator
Digital indicator
Stable light
reception indicator
Frequency indicator
Upper application indicator
Lower application indicator
Upper application
indicator
Lower application
indicator
Emitter: Operation indicator
Receiver: OSSD indicator
Emitter: Test indicator
Receiver: Interlock indicator
Содержание WUME-SF4D-2
Страница 2: ... Panasonic Industrial Devices SUNX Co Ltd 2016 2 MEMO ...
Страница 126: ...Functions Panasonic Industrial Devices SUNX Co Ltd 2016 126 MEMO ...
Страница 130: ...Maintenance Panasonic Industrial Devices SUNX Co Ltd 2016 130 MEMO ...
Страница 172: ... Panasonic Industrial Devices SUNX Co Ltd 2016 172 MEMO ...