![Panasonic WUME-SF4D-2 Скачать руководство пользователя страница 101](http://html1.mh-extra.com/html/panasonic/wume-sf4d-2/wume-sf4d-2_instruction-manual_3722659101.webp)
Functions
© Panasonic Industrial Devices SUNX Co., Ltd. 2016
101
Manual reset: The control output (OSSD 1 / 2) does not automatically turn ON when the device
is in the light-receiving state. The control output (OSSD 1 / 2) turns ON when the
device is reset [open test / reset input → short to +V when using PNP output or
short to 0V when using NPN output → open] in the light-receiving state.
<Timing chart>
150ms to 4 sec.
100ms or less
(Note)
Open (OFF)
Light received
Shorted (ON)
Light blocked
ON
OFF
Test / Reset input
Light received
state
Control output
(OSSD 1 / 2)
Note: The response time depends on the number of beam channels.
Response time (OFF response)
Main sensor
Sub sensor
Number of units in
series connection
1 unit
1 unit 2 units 3 units 4 units 0 unit 0 unit 1 unit 1 unit 2 units 2 units 3 units
Number of units in
parallel connection
0 unit 0 unit 0 unit 0 unit 1 unit 2 units 1 unit 2 units 1 unit 2 units 1 unit
Number of beam channels
4 to 48
6ms
10ms 10ms 12ms 12ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms
49 to 96
8ms
10ms 10ms 12ms 12ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms
107 to 127
10ms
12ms 12ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms
128 to 144
−
12ms 12ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms
145 to 192
−
14ms 14ms 16ms 16ms 14ms 14ms
−
−
−
−
−
193 to 256
−
16ms 16ms 18ms 18ms
−
−
−
−
−
−
−
Auto reset: The control output (OSSD 1 / 2) automatically turns ON when the device is in the light-receiving state.
<Timing chart>
(Note)
50ms or less
Light received
Light blocked
ON
OFF
Light received
state
Control output
(OSSD 1 / 2)
Note: The response time depends on the number of beam channels.
Response time (OFF response)
Main sensor
Sub sensor
Number of units in
series connection
1 unit
1 unit 2 units 3 units 4 units 0 unit 0 unit 1 unit 1 unit 2 units 2 units 3 units
Number of units in
parallel connection
0 unit 0 unit 0 unit 0 unit 1 unit 2 units 1 unit 2 units 1 unit 2 units 1 unit
Number of beam channels
4 to 48
6ms
10ms 10ms 12ms 12ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms
49 to 96
8ms
10ms 10ms 12ms 12ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms
107 to 127
10ms
12ms 12ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms
128 to 144
−
12ms 12ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms
145 to 192
−
14ms 14ms 16ms 16ms 14ms 14ms
−
−
−
−
−
193 to 256
−
16ms 16ms 18ms 18ms
−
−
−
−
−
−
−
<Reference>
The conditions for interlock activation can be changed using the communication module
SF4D-TM1
(option) and Configurator Light Curtain software.
Содержание WUME-SF4D-2
Страница 2: ... Panasonic Industrial Devices SUNX Co Ltd 2016 2 MEMO ...
Страница 126: ...Functions Panasonic Industrial Devices SUNX Co Ltd 2016 126 MEMO ...
Страница 130: ...Maintenance Panasonic Industrial Devices SUNX Co Ltd 2016 130 MEMO ...
Страница 172: ... Panasonic Industrial Devices SUNX Co Ltd 2016 172 MEMO ...