background image

Information on Disposal for Users of Waste Electrical & Electronic Equipment (private households)

This symbol on the products and/or accompanying documents means that used electrical and electronic products should not be
mixed with general household waste.
For proper treatment, recovery and recycling, please take these products to designated collection points, where they will be
accepted on a free of charge basis. Alternatively, in some countries you may be able to return your products to your local retailer
upon the purchase of an equivalent new product.
Disposing of this product correctly will help to save valuable resources and prevent any potential negative effects on human
health and the environment which could otherwise arise from inappropriate waste handling. Please contact your local authority

for further details of your nearest designated collection point.
Penalties may be applicable for incorrect disposal of this waste, in accordance with national legislation.

For business users in the European Union

If you wish to discard electrical and electronic equipment, please contact your dealer or supplier for further information.

Information on Disposal in other Countries outside the European Union

This symbol is only valid in the European Union.
If you wish to discard this product, please contact your local authorities or dealer and ask for the correct method of disposal.

For U.S., Canadian and Puerto Rican fields:

Panasonic System Solutions Company

Unit Company of Panasonic Corporation of North America

Security Systems

www.panasonic.com/security
For customer support, call 1.877.733.3689

Executive Office: 

Three Panasonic Way 2H-2, Secaucus, New Jersey 07094

Zone Office
Eastern: 

Three Panasonic Way, Secaucus, New Jersey 07094

Central: 

1707 N. Randal Road, Elgin, IL 60123

Southern: 

1225 Northbrook Parkway, Suwanee, GA 30024

Western: 

6550 Katella Ave., Cypress, CA 90630

Panasonic Canada Inc.

5770 Ambler Drive,Mississauga, 
Ontario, L4W 2T3 Canada (905)624-5010
http://www.panasonic.ca

Panasonic Sales Company

Division of Panasonic Puerto Rico Inc.
San Gabriel Industrial Park 65th Infantry Ave. KM. 9.5 Carolina
P.R. 00985(809)750-4300

© 2006 Matsushita Electric Industrial Co., Ltd. All Rights Reserved.

Ns1106-5087       3TR004689FAA       Printed in China

For European and other fields:

Matsushita Electric Industrial Co., Ltd.

Osaka, Japan
http://panasonic.net

Importer's name and address to follow EU rules:

Panasonic Testing Centre
Panasonic Services Europe GmbH
Winsbergring 15, 22525 Hamburg F.R.Germany

Содержание WJRT416 - 16CH DIGITAL RECORDER

Страница 1: ...R ALARM RESET OPERATE REV FWD SKIP Digital Disk Recorder WJ RT416 Digital Disk Recorder Installation Guide Model Nos WJ RT416 WJ RT416V WJ RT416 is shown above Before attempting to connect or operate this product please read these instructions carefully and save this manual for future use No model number suffix is shown in this Operating Instructions ...

Страница 2: ...ING TO QUALIFIED SERVICE PERSONNEL CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING This apparatus must be earthed Apparatus shall be connected to a mains socket outlet with a protective earthing connection The mains plug or an appliance coupler shall remain readily operable To prevent fire or electric shock hazard do not expose this apparatus to rain or moisture The apparatus should not be expo...

Страница 3: ...cordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense FCC Caution To assure continued compliance example use only shielded interface cables when connecting to com puter or peripheral de...

Страница 4: ...F OR RELATING TO THE PRODUCT 2 PERSONAL INJURY OR ANY DAMAGE CAUSED BY INAPPROPRIATE USE OR NEGLIGENT OPERATION OF THE USER 3 UNAUTHORIZED DISASSEMBLE REPAIR OR MODIFI CATION OF THE PRODUCT BY THE USER 4 ANY PROBLEM CONSEQUENTIAL INCONVENIENCE OR LOSS OR DAMAGE ARISING OUT OF THE SYS TEM COMBINED BY THE DEVICES OF THIRD PARTY 5 ANY CLAIM OR ACTION FOR DAMAGES BROUGHT BY ANY PERSON OR ORGANIZATION ...

Страница 5: ... your outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the app...

Страница 6: ...3 Check HDD information 33 Format the HDD 35 Operate the recorder using a PC 38 Functions and their descriptions 38 System requirements for a PC 38 Installation 39 HDD safety mode 39 Operating the recorder for the first time 39 Installation 39 HDD replacement 40 HDD addition 40 Rack mounting 41 Connection 42 Basic connection 42 Connection with RS485 cameras 43 Connection with PS Data systems 44 Co...

Страница 7: ...t data loss from disk failures Write error may occur frequently after around 20 000 hours of operation and the head and motor deterioration may occur and will reach their lifetime after 30 000 hours of operation when they have been used at the recommended ambient temperature approx 25 C 77 F When hard disk drive trouble occurs replace it immediate ly Consult your dealer for servicing When replacin...

Страница 8: ...hard disk drives may lead to personal information leakage When it is necessary to dispose or give this product to someone even when for repair make sure that there is no data on the hard disk drives Indication label Refer to the indication label placed on the surface of the unit as to the indications of equipment classification and power source etc Just in case make a note of your settings and sav...

Страница 9: ... Functions Real time recording Images from all connected cameras up to 16 can be recorded at 30 ips Timer recording It is possible to perform recording automatically at a scheduled time on a designated day of the week Terminal recording Recording will start automatically when an event occurs such as when a signal is input from a sensor etc Video motion detection function VMD Recording will start a...

Страница 10: ...he Adobe Reader is not installed on the PC download the latest Adobe Reader from the Adobe web site and install it The illustrations of the setup menus in this installation guide are of the NTSC model Microsoft Windows Windows Media Windows Media Player and DirectX are either registered trademarks or trademarks of Microsoft Corporation in the United States and or other countries Adobe and Reader a...

Страница 11: ...play press this but ton again u Multi screen button MULTI SCREEN Images from the connected cameras will be displayed on a multi screen 4 6 9 16 when this button is pressed Each time this button is pressed the multi screen will change as follows 16 CAM1 CAM16 4A CAM1 CAM4 4B CAM5 CAM8 4C CAM9 CAM12 4D CAM13 CAM16 6A CAM1 CAM6 6B CAM7 CAM12 9 CAM1 CAM9 16 CAM1 CAM16 i Alarm reset button ALARM RESET ...

Страница 12: ...cording will stop This button lights orange during recording 9 Fast reverse playback button REV Press this button to start fast reverse playback Playback speed can be changed in 6 steps page 22 When this button is pressed during pausing the previous frame is displayed 0 Fast forward playback button FWD Press this button to start fast forward playback Playback speed can be changed in 7 steps page 2...

Страница 13: ...d onto it 1 Audio in Alarm out terminal D SUB 25 pin AUDIO IN ALARM OUT Connect an alarming device such as a buzzer or an alarm lamp to this terminal When a device such as a microphone amplifier is connected audio from it will be input Audio being input to this terminal will be output from the AUDIO OUT connector of the unit and the con nected PC 2 Alarm in Control terminal D SUB 25 pin ALARM IN C...

Страница 14: ... 16 Images video signals from the cameras connected to the VIDEO IN connectors will be looped through to the VIDEO OUT connectors Connect system cameras or combination cameras to the VIDEO IN connectors The VIDEO IN 1 4 connec tors are compatible with coaxial cable When connect ing a combination camera connect it either to the VIDEO IN 1 4 connectors ...

Страница 15: ...a 16 screen numbers 1 16 will be displayed as shown in the illustration regardless of the camera title setting Cam1 MANUAL NQ PLAY Sep 03 2006 03 00 00PM Playback Timer recording Sequential display Playback status PLAYBACK Terminal recording VMD recording Information of the recorded images currently being played Time and date of recording Recording icon indicates that recording is in progress Live...

Страница 16: ...AL model connect the power cord to a 220 240 V AC 50 Hz outlet x Press the power button to turn on the power of the recorder The OPERATE indicator will light and the system check will start In the process of the system check the startup win dow will be displayed on a monitor When the system check is completed live images from the connected cameras will be displayed ...

Страница 17: ...g the camera selection buttons 1 10 0 Step 3 Move the cursor to Time Zone and then select a time zone using the skip buttons s d Step 4 When completing the adjustment move the cursor onto SET and press the OK button The adjusted time and date will be applied Important When the clock is adjusted during recording some of the recorded images cannot be searched Setup Menu System Setup Recording Setup ...

Страница 18: ...fer to page 21 for how to stop the timer recording or the alarm recording When playing recorded images stop playback Press the STOP button x Press the power button on the rear panel after confirming that all the HDD access indicators are off When the power supply is cut the OPERATE indicator will go off Important Unplug when unused for long period of time When the recorder has not been used for a ...

Страница 19: ...he audio mute press the ESC button again Important The audio mute will be applied to all camera channels Audio will be recorded with images even when muted during recording It is impossible to mute only a specified camera channel Display images from cameras on a multi screen Images can be displayed on the following multi screens 4 split screen 6 split screen 9 split screen 16 split screen Each tim...

Страница 20: ...ential display icon will be displayed To stop the sequential display press the SEQUENCE button again Sequential display on a 4 split screen z Make sure that images are displayed on a 4 split screen and then press the SEQUENCE button The sequential display will start and the icon sequential display icon will be displayed To stop the sequential display press the SEQUENCE button again Notes The dwell...

Страница 21: ...Timer recording It is possible to start and stop recording according to a recording schedule set in advance Recording schedule can be set on the setup menu Recording Setup Timer Rec Setup page 57 Important The timer recording cannot be stopped by holding down the REC button for 2 seconds or more To stop the timer record ing select Off for each day of the week and for DAILY on the setup menu Record...

Страница 22: ...ed images whose image quality and recording rate are low audio may not be heard properly c To stop playback press the STOP button When displaying recorded images on a multi screen press the STOP button after selecting the area of camera channel 1 When the lit PLAY button goes off and the playback stops the icon playback icon will also disappear Available functions when playing images Fast forward ...

Страница 23: ...gain Frame by frame forward playback When the FWD button is pressed during pausing frame by frame forward playback will start Frame by frame reverse playback When the REV button is pressed during pausing frame by frame reverse playback will start Interval of the frame by frame reverse playback will be determined by the I Frame Interval setting Recording Setup Common Setup Advanced Setup I Frame In...

Страница 24: ... button Step 1 Move the cursor onto each setup item and set the search filter Camera No Enter the camera channel number to be played using the camera selection buttons 1 10 0 Start Enter the start time and date of recording to be played using the camera selection buttons 1 10 0 Time and date that is specified minutes ago from the cur rent time will be automatically displayed The difference between...

Страница 25: ...ng the start and end time and date using the camera selection buttons 1 10 0 Filtering Select the recording type and the alarm recording type to be searched using the skip buttons s d Off Searches without filtering Manual Searches for only images recorded manually Timer Searches for only images recorded by the timer recording Alarm Searches for only images recorded by the alarm recording Terminal ...

Страница 26: ... Refer to page 22 for further information about playback operations Note The latest 5 000 recorded images will be displayed in the list form Prev Next Return Search List Cam Quality Start 08 07 06 05 04 03 02 01 SF FQ SF NQ EX SF FQ SF 01 24 2006 01 24 2006 01 24 2006 01 24 2006 01 24 2006 01 24 2006 01 24 2006 01 24 2006 10 43 22 10 43 22 10 43 22 10 43 22 10 43 22 10 43 22 10 43 22 10 43 22 01 2...

Страница 27: ...notification to the connected system device at an event occurrence Alarm output Outputs an alarm signal from the ALARM IN CONTROL terminal on the rear of the recorder in order to activate an alarming device when installed Refer to page 60 for how to configure the alarm output port settings Displays images from the camera to which an event has occurred on a single screen Alarm spot Refer to page 58...

Страница 28: ...ail addresses Refer to the operating instructions of the monitoring software PDF on the provided CD ROM for how to configure the settings Provide notification of an event occurrence to the PC according to the setting of Panasonic alarm protocol Notification of an event error occurrence time and date event error type can be automatically provided to the PC accord ing to the settings of Panasonic al...

Страница 29: ...shot 1 Display the Copy window by pressing the COPY button Step 1 Search for recorded images to be copied by setting each search filter on the Copy window Camera No Enter the camera channel number to be searched using the camera selection buttons 1 10 0 Start End Designate the time period to be searched by entering the start and end time and date Filtering Select the recording type and the alarm r...

Страница 30: ...ed only recorded images will be copied When Copy B is selected the viewer image player will be copied together with recorded images Copying will start When copying is completed the copy completion mes sage window will be displayed When the SET button is pressed in the process of copying the dialog box asking you whether you wish to cancel the copying or not will be displayed When clicking the OK b...

Страница 31: ...Enter the user password Important According to your needs select Disable for Auto Login User on the setup menu System Setup Auto Login User page 53 When Disable is not selected a user who logged out will automatically logged in as the registered auto login user when no operation had been made for around 1 minute after logout Log out Screenshot 1 Display the setup menu by pressing the SETUP button ...

Страница 32: ...ngs can be edited on the setup menu User Management User Level Setup page 66 When being logged out the user level of Viewer will be applied 2 Depending on the user level the available operations of the setup menu varies as follows Operator Logout alarm log reference error log reference system information reference current recording setting dis play Viewer Logout only Input Password Logout 1 9 9 9 ...

Страница 33: ...enance Screenshot 2 The Maintenance window will be displayed Step 2 Move the cursor onto Disk Management and then press the SET button Maintenance Alarm Log Error Log System Information Current Recording Setting Disk Management Online User Information Factory Default Reboot System Advanced Information Screenshot 3 The Disk Management window will be displayed Step 3 The status of the active built i...

Страница 34: ...er limitation even though the HDD is in the normal state Disk Type Unfitting Indicates that the model number and the disk size of the newly mounted HDD is dif ferent from the replaced HDD Step 4 Move the cursor onto Information and then press the SET button Step 5 Check time and date of the oldest data and the latest data and then press the SET button Screenshot 4 The Disk Information window will ...

Страница 35: ...s impossible to format it Format all the HDDs Screenshot 1 Display the Disk Management window page 33 Step 1 Move the cursor onto All Format and then press the SET button The confirmation window will be displayed Move the cursor onto OK and then press the SET button All Format Information Return REC Start Format STOP Change HDD Disk Management No 1 2 3 4 232 884GB 232 884GB 232 884GB 5 No Disk Det...

Страница 36: ...o Disk Detected 6 No Disk Detected 232 884GB 232 250GB 232 250GB 000 008GB 400h 400h 389h Capacity Used Hour Meter Screenshot 2 The following message window will be displayed after around 30 seconds Step 2 Replace the HDD Contact your dealer when it is necessary to replace the HDD Step 3 When completing the HDD replacement press the SET button OK Replace HDD The power supply of the HDD have been t...

Страница 37: ...t When there is nothing wrong with the HDD manage ment information the confirmation window will be dis played Press the SET button the Disk Management window will be displayed again When there is something wrong with the HDD manage ment information the message window asking whether or not to restore the HDD management information will be displayed To restore the HDD management information press th...

Страница 38: ...e recorder and the PC System requirements for a PC It is recommended to operate the monitoring software on a PC that meets the following system requirements If using a PC that does not meet the following system requirements it may cause problems such as slow imaging or the software becomes inop erable OS Microsoft Windows XP Professional SP2 Microsoft Windows XP Home Edition SP2 Tested and confirm...

Страница 39: ...llowing message will be displayed ALL HDD MOTORS STOPPED PRESS SET BUTTON TO RESTART Press the SET button to start up the recorder Installation When installing uninstalling the recorder into from the rack after starting operation of the recorder in the system do the follow ing z Restart the recorder using the setup menu Maintenance Reboot System page 70 x The message SYSTEM SETTING will be display...

Страница 40: ...e power supply to the HDD before starting the HDD replacement Refer to page 36 for how to stop the power supply to the HDD Contact your dealer when it is necessary to replace the HDD HDD addition When the indication No Disk Detected is displayed in the Disk Management window an HDD can be added to the recorder It is necessary to turn off the power of the recorder before adding a new HDD The record...

Страница 41: ...ts in the rack by using four rack mounting screws Rack mounting Remove the rubber feet Rack mount bracket fixing screw provided Rack mount bracket provided Rack mounting screw M5 x12 locally procured Important Keep the temperature in the rack below 45 C 113 F Install the recorder in the rack as low as possible and make a space of 1 unit 44 mm 1 73 between the recorder and the other mounted applian...

Страница 42: ... recorder is 900 1 200 m Use 5C 2V cable to connect between the recorder and the camera Select a proper value for the cable compensation setting Comp according to the actual length of the cable in use Otherwise images from the camera will not be displayed recorded correctly Audio signal from a microphone should be supplied to the recorder after amplifying to line level 10 dBv 51 kΩ by an amplifier...

Страница 43: ...2 14 13 12 11 10 9 8 7 6 5 4 3 2 1 16 15 MONITOR1 MONITOR2 RS485 CAMERA MODE DATA 10 100BASE T COPY1 ALARM IN CONTOROL AUDIO IN SIGNAL GND POWER ON OFF AC IN AUDIO IN ALARM OUT VIDEO SERIAL RS485 cable WV CA48 50 Unit number 12 Termination ON 4 wire connection Unit number 11 Termination OFF 4 wire connection Unit number 10 Termination OFF 4 wire connection Unit number 9 Termination OFF 4 wire conn...

Страница 44: ...mmunication Setup according to the system configuration The following are available PS Data compatible devices System controller WV CU650 Ver 2 10 or later Data multiplex unit WJ MP204 Matrix switcher WJ SX650 Ver 3 00 or later Any other PS Data compatible devices are not to be connected When connecting a single unit with a controller AUX IN AUDIO OUT IN OUT 16 15 14 13 12 11 10 9 8 7 6 5 4 3 5 3 ...

Страница 45: ...ND POWER ON OFF AC IN AUDIO IN ALARM OUT VIDEO SERIAL RS485 cable POWER ON OFF ALARM Data Multiplex Unit WJ MP204 ALARM SUSPEND 1 2 3 4 ESC SET RESET SUSPEND SET UP ALARM UNIT 0 9 8 7 6 5 4 3 2 1 Coaxial communication unit Termination ON Unit Address 2 1 ON 2 Mode selection DIP switches A B 1 3 2 4 6 5 7 9 8 0 SYSTEM CONTROLLER Controller Termination ON Unit Address 1 PS Data Setup of Communicatio...

Страница 46: ...ENCE SETUP COPY SEARCH ESC SET MULTI SCREEN ALARM RESET 1 5 9 13 2 3 4 6 7 8 10 0 11 12 14 15 16 Digital Disk Recorder WJ RT416 SKIP FWD REV STOP PLAY PAUSE REC REC STOP LAN cable 10BASE T 100BASE Tx category 5 cross IP address 192 168 0 250 Subnet mask 255 255 255 0 IP address 192 168 0 x except 0 250 and 255 Subnet mask 255 255 255 0 LAN LAN cable 10BASE T 100BASE Tx category 5 straight PC PC Hu...

Страница 47: ...ate both devices on both ends of the connection if they are connected with the RS485 cable Termination of this unit can be set with the DIP termination switch on the rear panel and the setting of the mode selection DIP switch varies whether to use this unit as a receiver or a system controller When connecting to the system controller and this unit is connected as the end of the PS Data connection ...

Страница 48: ...to the DATA port 48 Mode selection DIP switch The dip switch positions are defined by the attribute of the unit connected to the system s DATA terminal 1 2 Controller System Device DIP switch 1 OFF ON DIP switch 2 ON OFF ...

Страница 49: ... CH10 Audio input CH11 Audio input CH12 Audio input CH13 Audio input CH14 Audio input CH15 Audio input CH16 Signal GND Alarm 1 Output COMMON Alarm 1 Output NO Alarm 1 Output NC Alarm 2 Output COMMON Alarm 2 Output NO Alarm 2 Output NC Alarm 3 Output COMMON Audio input CH7 Audio input CH8 Audio input CH9 Audio input CH10 Audio input CH11 Audio input CH12 Audio input CH13 Audio input CH14 Audio inpu...

Страница 50: ...the recorder will be set to 00 min by signal input Time correc tion range 15 minutes Signal output upon an error detection Thermal error 47 C 117 F or high er fan error video loss password entry failure 3 times straight incorrect password entry no HDD detection Signal output upon a HDD error detec tion Not available Non voltage make contact input pulse width 100 ms or more Non voltage make contact...

Страница 51: ...unication Setup Network Setup Configure the basic settings relating to the network connection RS485 Setup Configure the RS485 settings PS Data Setup Configure the PS Data settings User Management User Level Setup Configure the operational level of operator and viewer for each channel Password Set the password for each user level Logout Log out the recorder Maintenance Alarm Log Log of event occurr...

Страница 52: ...mmon Setup Manual Rec Setup Timer Rec Setup Screenshot 3 The setup window of the selected submenu will be dis played Example When Common Setup is selected Step 3 Configure each setting on the setup window To select the setup item Move the cursor onto the desired setup item using the arrows button CDAB To change the parameter to move the cursor on the setup window Press the SKIP s or SKIP d button ...

Страница 53: ...p Advanced The following window will be displayed when the Set but ton is pressed after moving the cursor onto Set Date Format Select a time format from the following Example October 5 2006 yyyy mm dd 2006 10 05 mmm dd yyyy Oct 05 2006 mm dd yyyy 10 05 2006 dd mm yyyy 05 10 2006 dd mmm yyyy 05 Oct 2006 Default mmm dd yyyy NTSC model dd mm yyyy PAL model Note Display of month will be mm numeric exc...

Страница 54: ...efault Off Summer Time DST Table Set the start end date and time for summer time The follow ing window will be displayed when the SET button is pressed after moving the cursor onto Set Default As shown in the illustration above Auto Data Delete Configure the settings to delete recorded images automati cally when the set days have passed from the day the images were recorded 000 200 Days When 000 i...

Страница 55: ...rded images when the available disk space is running out On Overwrite recorded images Off Do not overwrite recorded images Default On Audio Select Select On or Off for each camera channel to determine whether or not to record images with audio The following window will be displayed when the SET but ton is pressed after moving the cursor onto Set On Record audio together with images Off Record only...

Страница 56: ... the resolution of recorded images The following window will be displayed when the SET button is pressed after moving the cursor onto Set Select a resolution for each camera channel from the fol lowing Field Standard NTSC model 704 x 240 PAL model 704 x 288 SIF Low NTSC model 352 x 240 PAL model 352 x 288 No recording and image transmission is carried out Default Field Common Setup Advanced Time P...

Страница 57: ...etup section Recording time range Set the start time and end time for the desired day of the week and then select On Up to 2 time ranges can be set as the timer recording schedule To set the same time range for every day of the week enter the start and end time for DAILY When On and Off of 2 different schedules are set in the same time range the timer recording will be carried out according to the...

Страница 58: ...es from the camera that is selected for Alarm Spot Camera No of Alarm Rec Setup Advance page 59 on a single screen at an event occurrence On Display images from the selected camera Off Do not display images from the selected camera Default On Note The screen that was displayed immediately before an event resumes after the event is finished Pre Alarm Recording Select On or Off to determine whether ...

Страница 59: ...0 24 00 Off Alarm Duration 2 00 00 24 00 AL M Note When AL M and AD M of 2 different alarm durations are set in the same time range the alarm action will be taken according to the setting for the alarm duration with AL M Term Rec Channel Set the camera channel to be used for the alarm recording upon a terminal input or a command alarm reception 00 16 When 00 is selected images from all of the came...

Страница 60: ...ng will not stop until the alarm is reset Default 030 sec Alarm Duration Set the active duration of the alarm action LED blinking buzzer sounding alarm output from the terminal on the rear of the recorder 001 999 Sec Default 030 Sec Alarm Output Port Select a port from which an alarm signal is output 0 4 When 0 is selected no alarm signal will be output Default 0 Alarm Spot Camera No Select a came...

Страница 61: ...nel 5 30 sec Default 5 sec Camera Allocation Setup Allocate the camera channels to the areas of multi screen 4 6 9 Move the cursor to the desired area of multi screen and determine the camera channel to be allocated to the selected area using the camera selection buttons 1 10 0 Default As shown in the illustration above Important The area allocated for camera channel 1 is impossible to change The ...

Страница 62: ...en the camera and the recorder is shorter than 500 m M Suitable when the total cable length between the cam era and the recorder is 500 900 m L Suitable when the total cable length between the camera and the recorder is 900 1 200 m Default S Notes To display the Camera Control Setup page for camera channels 9 16 click the 9 16 button The setting of compensation cable loss will be ignored when rece...

Страница 63: ...0M Half 10 Mbps half duplex 100M Full 100 Mbps full duplex 10M Full 10 Mbps full duplex Default Auto Configure the settings relating to communications with other devices Communication Setup It is necessary to conform the setting such as the communication protocol and the line speed when connecting an external device such as a system controller to the DATA port or the RS485 port It is also necessar...

Страница 64: ...p The following window will be displayed when the SET but ton is pressed after moving the cursor onto Set DNS Select Manual or Auto to enable IP address searching by the host name using the DNS Select Off when not using the DNS Selecting Auto is available only when On is selected for DHCP using the DHCP server When Manual is selected for the DNS enter the DNS serv er addresses in IP Address Primar...

Страница 65: ...er of an event occurrence from the following Off Does not function 0s Informs the controller every time an event is detect ed 1s 5s Informs the controller when a specified time has passed after detecting an event Default 1 s Camera Number Setup It is possible to assign a number to each camera chan nel to operate cameras using the controller compatible with PS Data Do the following to assign number...

Страница 66: ...ack OK Cancel Step 1 Select a camera channel to which this setting is to be applied Camera No When a camera channel is selected the current user level information of the selected camera channel will be displayed Note The camera selection buttons 1 10 0 are available for the camera channel selection Step 2 Configure the operational level of operator and viewer for the selected camera channel To all...

Страница 67: ... and Manager buttons on the bottom of the win dow Important Set a unique password not something that would be easily guessed by a third person The password also should be mem orable e Logout of the recorder Logout Refer to page 31 for how to log out of the recorder Confirm Manager 2 Manager 1 Manager 3 Manager 4 Cancel OK Operator Viewer Password Confirm Operator 2 Operator 1 Operator 3 Operator 4...

Страница 68: ...nd alarm n Alarm No w Check the Error Log Error Log The error logs time and date of the error occurrence and event will be displayed in the list form Up to 500 error logs can be kept and the older logs will be overwritten by the newer logs The following is the descriptions of the error log Thermal Error Fan a Error HDD Full Full Records Reached the maximum number of files possible to keep HDD n Ac...

Страница 69: ...ual recording timer recording alarm recording for each channel etc can be checked The Title setting can be configured with the monitoring software Refer to the operating instructions of the monitoring software PDF on the provided CD ROM for further information t Manage the HDDs Disk Management Format of the built in HDDs and restore of HDD management information list information of recorded images...

Страница 70: ...tton The selected user will be forcibly logged out u Reset the current settings to the default Factory Default It is possible to reset the settings to the default except the time and date setting When the SET button is pressed after selecting Factory Default the confirmation window will be displayed The settings except the time and date setting will be reset to the default when the SET button is p...

Страница 71: ...etwork Modify Auto Delete _ Modify Password L TC YYYY MM DD HH MM SS R TC YYYY MM DD HH MM SS Restore Default Settings HDD n Format HDD n Repair Directory HDD n Replace User Allow Overwrite _ Disconnect User HDD Safety Mode _ Data Copy Backup via Network L Operation using the buttons on the recorder R Operation using a PC via a network n HDD No User name M Manager O Operator V Viewer User number 1...

Страница 72: ...irmware Update and then press the SET button Versions of the current firmware and the new firmware will be displayed Step 3 Move the cursor onto OK and then press the SET button When the firmware upgrade is completed the recorder will reboot on its own Notes Before starting the firmware upgrade stop recording playback and the monitoring software operation The firmware will be overwritten and never...

Страница 73: ...the WV CU650 At the default setting of the WV CU650 it is possible to display the System Setup 301 submenu by pressing the F1 button while holding the SHIFT but ton down SHIFT F1 Same action as when AD M is selected for Alarm Duration of Terminal and VMD will be taken during the alarm suspension SETUP ESC Open Close SKIP SKIP F1 F2 Open the SETUP MENU Close the SETUP MENU or 1 2 or CAM SET or MON ...

Страница 74: ...ay ON Display the copy window Close the copy window Mute ON OFF It is possible to stop the sequential display by pressing the SEQ PAUSE SEQ STOP button while holding the SHIFT button down SHIFT SEQ PAUSE SEQ STOP Available only when the search window is being displayed SEQUENCE COPY TOUR SEQ GROUP SEQ F4 Camera selection buttons 1 16 Camera number SHIFT CAM FUNC SYS FUNC 8 0 1 8 1 6 5 When the sea...

Страница 75: ...ces on Confirm that the power of the cameras and the connected devices are on Are the cables connected correctly and firmly Confirm that the cables are connected correctly and firmly Are the brightness and contrast settings of the monitor adjusted correctly Check the settings Is the user level of the current login user set to allow moni toring of live images Confirm that the user level of the curr...

Страница 76: ...the camera control settings Check if alarm output signals are properly input to the AUDIO IN ALARM OUT or ALARM IN CONTROL terminal on the rear of the recorder When alarms occurred sequentially for a long period notifi cation mail of a new alarm occurrence may not be sent Check the settings for Event Setup Check if the built in backup battery has been worn out The lifetime of the battery is approx...

Страница 77: ...con nectors get hot during use The power cord gets hot when bent or stretched Cause solution Symptom Isn t the inserted disk incompatible with the internal CD DVD drive Is a disk placed on the disk tray correctly Isn t any external recording device connected to the COPY1 or COPY2 port Cannot copy recorded images onto a disk using the internal CD DVD drive Only when using the WJ RT416V The recorder...

Страница 78: ...kg 24 28 lbs WJ RT416 WJ RT416V 12 kg 26 49 lbs General Input Output Function Specifications Power source Video Power consumption Ambient operating temperature Ambient operating humidity Dimensions 120 V AC 60 Hz NTSC model 220 240 V AC 50 Hz PAL model VIDEO IN connectors Composite video input signal 1 V P P 75 Ω x16 input BNC Control signal multiplex x4 input CH1 CH4 CH5 CH8 when an optional boar...

Страница 79: ...00 GB 2 1500 GB 3 Rec Duration 24 hours day HDD capacity 500 GB 1 1000 GB 2 1500 GB 3 Standard accessories CD ROM 1 pc Installation Guide this book 1 pc Warranty only for NTSC model 1 set The following are included on the CD ROM Operating instructions of the monitoring software PDF Monitoring software RT4Client The following is for installation Power cable for NTSC model 1 pc Power cable for PAL m...

Страница 80: ... Information on Disposal in other Countries outside the European Union This symbol is only valid in the European Union If you wish to discard this product please contact your local authorities or dealer and ask for the correct method of disposal For U S Canadian and Puerto Rican fields Panasonic System Solutions Company Unit Company of Panasonic Corporation of North America Security Systems www pa...

Отзывы: