37
Video motion detector recording (VMD REC)
(1) Press the [MENU] button. "WJ-RT208 SETUP MENU"
appears. Move the cursor to "REC&EVENT SETUP" and
press the [SET] button. (Refer to steps (1) and (2) in
3.1.3.)
(2) Move the cursor to "VMD REC" and press the [SET] but-
ton.
Camera ID:
1-8
Default: 1
Sensitivity:
01 - 99 (01 corresponds to the maximum
sensitivity.)
Default: 10
Area setup:
140 grid areas can be established inde-
pendently.
Default: All areas are not selected.
Alarm output connector:
0-3
Default: 0 (0 indicates that there is no alarm signal
output.)
Alarm time:
000-999
Default: 030
Rec. Interval:
030-999
Default: 060
Camera preset position:
000-256
Default: 000
Picture quality:
"SP Fine/Fine/Good/Normal/Extended"
Default: "Normal"
Terminal input connector:
1 - 8
Default: 1
Alarm output connector:
0 - 3
Default: 0 (0 indicates that there is no alarm signal
output.)
Alarm time:
000 - 999
Default: 030
Rec. Interval:
030 - 999
Default: 060
Camera preset position:
000 - 256
Default: 000
Recording channel:
0 - 8
Default: 1
Picture quality:
"SP Fine/Fine/Good/Normal/Extended"
Default: "Normal"
Frame rate:
"Full, 1/2F, 1/4F, 1/8F, 1/16F"
Default: "Full"
Stream type:
"CBR/VBR"
Default: "CBR" (If screen changes seem extreme,
the setting made at "VBR" is preferable.)
Period:
"Period1/Period2"
Default: 00: 00 - 24:00
When "On" is selected for "Period1" and/or "Period2",
alarm detection will be validated in the set period.
Notes:
1. When setting is completed, set "Period1" and/or
"Period2" at "On".
2. For [All] operation and functions, refer to the timer
recording explanation.
(4) When setting is completed, move the cursor to [OK]
and press the [SET] button.
Note:
When trying to stop the recording by changing
the settings in the process of the terminal recording,
recording will not stop immediately. The terminal
recording will not stop unless time set for "Rec.
Interval" has been passed. To stop the terminal
recording, stop recording manually after changing
the settings for the terminal recording.
1
Terminal Input
0
Alarm Output
030
Alarm Time
060
Rec. Interval
Sec
Sec
000
PTZ Preset
1
Rec. Channel
Normal
Rec. Quality
00: 00
Period1
00: 00
Full
CBR
24: 00
24: 00
Off
On
Period2
All
OK
Cancel
TERMINAL REC
REC & EVENT
TIMER REC
TERMINAL REC
VMD REC
RECORD LENGTH
AUDIO SELECT
Channel No.
Sensitivity
Area Setup
Alarm Output
Rec. Interval
PTZ Preset
Rec. Quality
Period1
Period2
1
10
Set
0
030
Sec
Sec
060
000
Normal
Full
CBR
All
OK
Cancel
00: 00
00: 00
24: 00
24: 00
Off
Off
VMD REC
Содержание WJRT208 - Digital Disk Recorder
Страница 61: ...61 ...