-12-
SYSTEM 1
The input video signals for this unit are not synchronized.
Notes :
• When pressing the ALARM RESET/QUAD/SEQ/ECS button or the VIDEO SELECT/CURSOR/SELECT buttons, the pic-
ture on the video monitor may roll briefly at the time of switching.
• The video signal to be recorded by the VTR should be supplied from the VTR OUT connector of this unit and not from
the VIDEO OUT/ESC connector of this unit, unless VTR servo control disturbances are allowable when setting the
ALARM RESET/ QUAD/SEQ/ECS button or the VIDEO SELECT/CURSOR/SELECT buttons.
Connections
• Connect the VIDEO IN connectors of this unit to the video output connectors of the cameras.
• Connect the VTR OUT connector of this unit to the video input connector of the time lapse VTR for recording.
• Connect the VIDEO OUT connector of this unit to the video input connector of the video monitor.
VTR
OUT
1
VIDEO
OUT
ALARM/REMOTE
IN
OUT
2
VIDEO
IN
OUT
3
IN
OUT
4
IN
OUT
SIGNAL GND
Monitor
Monitor
VTR
WJ-MS424
VIDEO
VIDEO
VIDEO
VIDEO
SYSTEM CONNECTIONS