36
Notes:
• VMD should be used when the input to the unit is
from an ordinary camera. Select [OFF] to avoid use-
less VMD when a video multiplexer or combination
camera supplies the input to the unit.
• Set ALARM SUSPEND to ON when you do not want
VMD to be activated during the VMD setup.
• There may be cases where VMD does not suffi-
ciently detect changes, since it detects the
changes in luminance.
• The detection area may include areas slightly out-
side the border.
• The buzzer will beep if detection takes place during
the area setup.
4. Set the upper-left end of the detection area. Move the
asterisk to the right or left with the JogDial, and up or
down by pressing the [
D
] or [
C
] button.
5. Press the JogDial to enter the upper-left end of the
detection area. The asterisk position is highlighted.
6. Set the bottom-right end of the detection area similar to
steps 3 and 4 above.
7. Press the JogDial. The area is highlighted.
Up to 4 areas can be selected. These may partially
overlap. Repeat steps 3 to 6 to select more areas. To
deselect an area, move the cursor to the upper-left end
of the area, and press the JogDial.
■
Communication Setup
(COMMUNICATION SETUP)
Communication parameters are set to match those of the
connected devices and the system configuration. The serial
port setup and network setup are made.
■
Serial Port Setup
(SERIAL PORT SETUP)
The SERIAL PORT SETUP menu appears when it is select-
ed in the COMMUNICATION SETUP menu.
Note:
Parameters marked with * on the following pages are
default settings applicable to RS-232C.
●
Protocol (PROTOCOL)
1. Move the cursor to PROTOCOL with the [
D
] or [
C
] but-
ton.
2. Select a suitable protocol with the JogDial, and press
the JogDial.
The default is PS
•
DATA.
PS
•
DATA:
Select when the communication chain uses
the PS
•
DATA protocol.
This selection enables the DATA terminal on the
rear panel for communication.
RS-232C:
Select when a protocol other than PS
•
DATA
is used.
This selection enables the RS-232C terminal on the
rear panel for communication.
Note:
Parallel use of the DATA and RS-232C terminals
is not possible.
*
CAM1
PUSH
•
PAUSE
/
/
SET
REW/FF
/
STEP
/
q
w
e
r
SERIAL PORT SETUP
PROTOCOL PS•DATA
BAUD RATE 9600
DATA BIT 8
PARITY CHECK NONE
STOP BIT 1
WAIT TIME OFF
CTL-UNIT ADDR 1
SYS-UNIT ADDR 1
ALARM DATA 1S
CAM NO.SETUP
O
COMMUNICATION SETUP
SERIAL PORT SETUP
O
NETWORK SETUP
O
Содержание WJHD200 - Digital Disk Recorder
Страница 52: ...52 ...
Страница 53: ...53 WJ HD200 NETWORK OPERATION ...
Страница 77: ...77 SPECIFICATIONS APPENDIX ...