TROUBLESHOOTING
Problem
The hard disk drive is not rec-
ognized.
The unit runs in the SINGLE
mode.
MIX ERROR occurs. (The
SYS-2 SINGLERAID MIX
ERROR indication appears.)
• Is the HDD cable connected to the RAID board correctly and firmly?
• Is the HDD cable connected to the hard disk drive correctly and firmly?
• Is the HDD power cable connected to the hard disk drive correctly and firmly?
• Is the provided cable connected correctly and firmly?
• Is the jumper setting on the HDD set as the master?
• Set the unit to the RAID5 mode.
• Set the extension unit to the RAID5 mode.
• Is the unit running in the RAID5 mode?
• Is the extension unit running in the RAID5 mode?
Check item/Remedy
Check item/Remedy
The HDD access indicator
lights/blinks red.
• The respective HDD is failed in the RAID 5 mode. Refer to the dealer.
• The indicator respective to the HDD that failed first will light red and the indica-
tors for the other failed HDD will blink red.
The HDD access indicator
lights red and orange when
operating in the RAID 5 mode.
• The system error occurred. Refer to the dealer.
The system error status will be displayed with the HDD indicators as follows.
9
: Red,
8
: Orange
9 8 8 8
: Hardware malfunction
8 9 8 8
: Hardware malfunction
9 9 8 8
: Hardware malfunction
8 8 9 8
: Hardware malfunction
9 8 9 8
: Hardware malfunction
8 9 9 8
: Hardware malfunction
9 9 9 8
: Hardware malfunction
8 8 8 9
: Hardware malfunction
9 9 8 9
: Hardware malfunction
8 8 9 9
: Hardware malfunction
8 9 9 9
: Disk CRC error