39
■
Time and polarities of the ALARM/CONTROL terminal and the ALARM
terminal
Terminal
Active Time
Remarks
Alarm input
100 ms or more
L active
Alarm output
The set time on the Setup menu
L active
Network error output
Until the network error is cleared, or until the ERR button on
the operation window is clicked.
L active
Alarm reset input
100 ms or more
L active
Emergency recording input
100 ms or more
L active
Available disk capacity warning output
Duration set for "Error output duration"* starting from the time
of the error occurrence.
L active
HDD error output
Duration set for "Error output duration"* starting from the time
of the error occurrence.
L active
Camera error output
Duration set for "Error output duration"* starting from the time
of the error occurrence, or until the camera is reset (from the
time of the error occurrence).
L active
Error output
Duration set for "Error output duration"* starting from the time
of the error occurrence.
L active
Time adjustment I/O
Input: 100 ms or more
Output: 1 s
Input/Output: L active
Alarm suspension input
100 ms or more
L active, judged by level
External recording mode changeover
100 ms or more
L active
Outage detection input
5 s or more
L active
Outage processing end output
10 s or more
H active
* "Error output duration" can be set on the "Basic" page of the setup menu. (Refer to the setup instructions (PDF).)
Note:
• During "L active (Low active)", the logic will be implemented when the voltage level of signal is low.