40
11.4.6 DISPOSAL OF OUTDOOR UNIT DRAIN WATER
When a Drain elbow is used, please ensure to follow below:
o
the unit should be placed on a stand which is taller than 50 mm.
o
cover the 8 holes (ø20 mm) with Rubber cap (refer to illustration below).
o
use a tray (field supply) when necessary to dispose the outdoor unit drain water.
Rubber cap
Drain elbow
× 8
2
5
If the unit is used in an area where temperature falls below 0°C for 2 or 3 consecutive days, it is recommended
not to use the Drain elbow and Rubber cap , for the drain water freezes and the fan will not rotate.
Содержание WH-SXC16F9E8
Страница 28: ...28 10 1 2 Solar Printed Circuit Board Optional ...
Страница 46: ...46 57 C 57 C 57 C 57 C ...
Страница 47: ...47 ...
Страница 53: ...53 ...
Страница 54: ...54 ...
Страница 55: ...55 57 C 57 C 50 C 50 C ...