7
10
Booster Heater
To activate or deactivate the water tank’s booster heater.
Note: If NO is selected, menu 11 is skipped.
YES
NO
11
Booster Heater Delay Timer
To delay time for the booster heater to activate while the system is heating up
the water tank.
20 minutes ~
1 hour 35 minutes
• Do not use the system during sterilisation in order to prevent scalding with hot water, or overheating of shower.
• Ask an authorised dealer to determine the level of sterilisation function field settings according to the local laws and
regulations.
12
Sterilisation
To sterilise the water tank, if required.
Note: If NO is selected, menus 13 to 15 are skipped.
YES
NO
13
Sterilisation Day & Time
To set timer for sterilisation.
(Only once a week. Operates even under a standby condition)
Monday ~ Sunday
0:00 ~ 23:50
14
Sterilisation Temperature
To set the temperature of sterilisation.
40 °C ~ 75 °C
15
Continuation of Sterilisation
To maintain heating temperature in order to complete the sterilisation.
5 minutes ~
1 hour
16
Base Pan Heater
To select whether or not to connect to the optional base pan heater.
Note: If NO is selected, menu 17 is skipped.
YES
NO
17
Base Pan Heater type
Type A - The base pan heater activates only during deice operation.
Type B - The base pan heater activates when outdoor ambient temperature is
5 °C or lower.
A
B
18
*
1,
*
2
Cool Outdoor Temperature setting
To set the outdoor ambient temperature for the AUTO mode to change from
HEAT to COOL.
5 °C ~ 25 °C
19
*
1,
*
2
Heat Outdoor Temperature setting
To set the outdoor ambient temperature for the AUTO mode to change from
COOL to HEAT.
5 °C ~ 25 °C
20
Dry Concrete
During construction to dry the concrete under a preset temperature.
Do not use this menu for any other purposes and in period other than during
construction (refer to information page).
1 day ~ 99 days
User
Remote control preparation
1
Press
.
2
Press or to set the current day.
3
Press to confirm.
4
Repeat steps
2
and
3
to set the current time.
■
Note:
• The current day and time need to be set in cases below:
- When the power is turned on for the first time.
- A long time has elapsed since the power was turned on the
last time.
• The current time that has been set will be the standard time for
all the timer operations.
Caution Indicator (Tank Temperature above 60 °C)
Dealer
Operation/settings to be done only by the authorised dealer/specialist.
User
Operation/settings to be done by the authorised dealer/specialist or user.
*
1
The system is locked to operate without COOL mode. It can be unlocked only by authorized installers or our authorized service partners.
*
2
Only displayed when COOL mode is unlocked (Means when COOL mode is available).
English
To
adjust initial settings