43
Cleaning instructions
Regular Checks
Indoor unit
•
Do not splash water directly.
Wipe the unit gently with a soft dry cloth.
To ensure optimal performance of the system, cleaning has to be carried out at regular intervals.
Consult an authorised dealer.
•
Disconnect the power supply before cleaning.
•
Do not use benzine, thinner or scouring powder.
•
Use only soap ( pH7) or neutral household detergent.
•
Do not use water hotter than 40 °C.
Water pressure check
•
Ensure that the water pressure is between
0.5 bar and 3.0 bar.
•
In case the water pressure is out of the
above range, consult an authorised dealer.
•
Water pressure can be checked through
following method:-
Go to System check > System information >
Water pressure
Water
fi
lter
•
Clean the water
fi
lter at least once a year. Failure to do
so may cause the
fi
lter to clog up, which may lead to
system breakdown. Consult an authorised dealer.
•
Please remove the magnet and remove the accumulated
dust inside. (Bottle type)
•
Please also remove dust on the magnet. (Valve type)
Water Filter Set
Outdoor unit
•
Do not obstruct the air inlet and outlet vents. Failure
to do so may result in low performance or system
breakdown. Remove any obstruction to assure the
ventilation.
•
When it snows, clean and remove snow around the
outdoor unit to prevent the air inlet and outlet vents from
being covered with snow.
Tips: For extended non-use
•
The water inside the Tank should be drained.
•
Disconnect the power supply.
Info: Non serviceable criteria
Disconnect the power supply
then please consult an authorised dealer under the
following conditions:
•
Abnormal noise during operation.
•
Water/foreign particles have entered the Remote
Controller.
•
Water leaks from the indoor unit.
•
Circuit breaker switches off frequently.
•
Power cord becomes excessively warm.
Sanitary Water Tank
Safety relief valve
This Air-to-Water Hydro Tank have two safety
valves, one for the (TANK) in indoor unit and one for the
(CIRCUIT) in outdoor unit.
•
The TANK’s safety relief valve sometimes releases a
little water after hot water usage. This is because the
cold water, which enters the water heater, expands when
heated, causing the pressure to rise and the safety valve
to open.
•
The CIRCUIT’s safety relief valve must be completely
closed and must not normally release any water.